Removing the fabric enclosure and top cover
Installing an RPM series pressure monitor
Both the top cover and the fabric enclosure are fastened
to the mobile containment unit via hook and loop. To
remove the top cover, simply separate the hook and
loop along the perimeter of the top cover. To remove
the fabric enclosure, detach the hook from the loop from
each of the four telescoping members as shown above.
Then separate the hook and loop along the top
perimeter and then the bottom perimeter.
Locate
bracket on the inside back wall of the
AG8000.
Remove the faceplate from the RPM series
pressure monitor by unscrewing the two small
screws on the sides of the pressure monitor.
Connect the reducing elbow to the "COM"
port of the monitor and attach tubing to the
other side of the elbow. Plug the power
connector into the terminal as shown. Hang
the monitor on the lower set of screws on the
mounting bracket.
Plug the tubing into the barb located in the
polycarbonate panel of the back wall.
Reattached the faceplate to the monitor by
tightening the two screws on the sides. Plug
the power adapter into one of the standard
120V receptacles inside the AG8000.
13
the
pressure monitor
mounting