Dell 6100 Donanım Kılavuzu - Sayfa 11
Sunucu Dell 6100 için çevrimiçi göz atın veya pdf Donanım Kılavuzu indirin. Dell 6100 15 sayfaları. Dell poweredge 4200 servers: installation guide
Ayrıca Dell 6100 için: Raf Kurulumu (37 sayfalar), Ek Kılavuz (4 sayfalar), Raf Kurulumu (34 sayfalar)
CAUTION: Never remove the heat sink from a microprocessor
unless you intend to remove the microprocessor. The heat sink is nec-
essary to maintin proper thermal conditions
Press down on the folded part of the clip with a small screwdriver to release
the clip.
heat sink
socket
release lever
Figure 7. Microprocessor Securing Clip
4. Remove the heat sink.
The thermal interface pad is bonded to the heat sink and will remain
attached to the old heat sink.
5. Push outward and then upward on the release lever to rotate the lever
to its fully vertical position (see Figure 8).
CAUTION: Be careful not to bend any of the pins when removing
the microprocessor chip from its socket. Bending the pins can perma-
nently damage the microprocessor chip.
microprocessor
securing clip hooks
over tabs on socket
(front and back)
microprocessor
socket
microprocessor
Dell PowerEdge 6100/200 System Microprocessor Replacement
9