Dell EMC PowerEdge XE8545 Teknik Özellikler - Sayfa 18
Sunucu Dell EMC PowerEdge XE8545 için çevrimiçi göz atın veya pdf Teknik Özellikler indirin. Dell EMC PowerEdge XE8545 33 sayfaları.
System diagnostics and indicator codes
This section describes the diagnostic indicators on the system front panel that displays the system status during system startup.
The following sections contain information about the chassis LEDs and indicator codes for the PowerEdge XE8545 system.
Topics:
•
Status LED indicators
•
System health and system ID indicator codes
•
GPU fan LED indicator codes
•
iDRAC Direct LED indicator codes
•
LCD panel
•
NIC indicator codes
•
Power supply unit indicator codes
•
Drive indicator codes
•
Using system diagnostics
•
System board diagnostic LED indicators
Status LED indicators
NOTE:
The indicators display solid amber if any error occurs.
Figure 6. Status LED indicators
Table 26. Status LED indicators and descriptions
Icon
Description
Drive indicator
Temperature
indicator
18
System diagnostics and indicator codes
Condition
The indicator turns solid amber if
there is a drive error.
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
Corrective action
● Check the System Event Log to determine if the
drive has an error.
● Run the appropriate Online Diagnostics test.
Restart the system and run embedded
diagnostics (ePSA).
● If the drives are configured in a RAID array,
restart the system, and enter the host adapter
configuration utility program.
Ensure that none of the following conditions exist:
● A cooling fan has been removed or has failed.
● System cover, air shroud, or back filler bracket is
removed.
● Ambient temperature is too high.
● External airflow is obstructed.
3