Filter Replacement

THE DEVICE MUST BE ISOLATED FROM THE
!
POWER SUPPLY BEFORE ANY REPLACING FILTERS
Only use genuine DH Lifelabs Filters. Use of any other filters may compromise
!
the proper operation of your unit and potentially void your warranty.
FILTERS ARE NOT WASHABLE. DO NOT IMMERSE IN WATER.
!
Activated Carbon (AC) Filter Replacement
The AC filter should be replaced every 6 months or when indicated by the alternating flashing red and
blue light. This interval is only a recommendation. The filter may need to be replaced earlier or later
depending on how often it's used and the environment surrounding the device.
1. Remove the security screw and open the front cover.
2. Remove the old AC filter from the unit box and dispose according to local regulations.
3. Remove protective packaging from the new AC filter and insert it into the unit box.
4. Locate the cleaning brush on the front of the unit box and use to clean the PlasmaShield emitters
(see page 19) and replace brush back in the front of the unit box.
5. Install the unit box in the device.
6. Install the cover and secure with screw.
HEPA Filter Replacement
The HEPA filter should be replaced every 18 months or when indicated by the alternating flashing red
and green light. This interval is only a recommendation. The filter may need to be replaced earlier or later
depending on how often it's used and the environment surrounding the device.
1. Remove the security screw and open the front cover.
2. Remove the old HEPA filter and dispose according to local regulations.
3. Remove protective packaging from the new HEPA filter and insert it into the device.
4. Install the cover and secure with screw.
To purchase replacement filters please call 1-877-548-9722 or email [email protected]
HEPA Filter: Part No. DH11FT-1
AC Filter: Part No. DH11FT-2
19

Cleaning and Maintenance

THE DEVICE MUST BE ISOLATED FROM THE
!
POWER SUPPLY BEFORE ANY REPLACING FILTERS
CAUTION: ALWAYS WEAR SUITABLE GLOVES WHEN CLEANING.
!
!
• Remove any dirt from the sensor area.
• Use a dry cloth to clean the exterior of the device. Do not use any chemicals or cleaners.
• It is recommended that the interior of the device be inspected at least once a year and cleaned as
necessary, or if performance degrades. Heavy use or an environment containing a high amount of lint,
dust or other particles, requires more frequent cleaning. Particles on the air inlet, pre-filter and other
internal parts of the device can reduce efficiency and shorten the lifespan of the parts.
• Use cleaning brush located on the front of the AC unit box to clean the PlasmaShield emitters .This can
be done when replacing the AC filter.
• It's recommended to clean the pre-filter with water every 3-6 months to increase efficiency.
• When the device is not used for an extended time, store it in a cool dry place. Do not store the device
where it might be exposed to excess moisture or direct sunlight.
• The device may not operate effectively in very low temperatures. The device can be damaged when
exposed to sub-freezing temperatures.