Dell PowerEdge 1655MC Tamamlayıcı Kılavuz - Sayfa 10
Sunucu Dell PowerEdge 1655MC için çevrimiçi göz atın veya pdf Tamamlayıcı Kılavuz indirin. Dell PowerEdge 1655MC 24 sayfaları. Removing a fan
Ayrıca Dell PowerEdge 1655MC için: Donanım Kılavuzu (10 sayfalar), Donanım Kılavuzu (14 sayfalar)
Replacing the Server Module Board
The following procedures are required to replace the server module board. You must follow
the procedures in the order given.
Removing the Server Module
CAUTION: See your System Information Guide for complete information about
safety precautions, working inside the computer, and protecting against
electrostatic discharge.
Ensure that the server module's power is off.
1
The blinking green power-on indicator shows that power is available to the system. If
the power-on indicator is solid green, press the module's power button to turn off the
module. See Figure 1-1.
Using a #2 Phillips screwdriver, loosen the captive screw that secures the server
2
module's ejector handle to the front of the server module. See Figure 1-2.
Grasp the server module's handle and rotate the handle down to eject the server
3
module from the chassis. See Figure 1-2.
Grasp the server module and slide it out of the chassis. See Figure 1-2.
4
F i g u r e 1 - 2 .
1-6
Repl aci ng the S er v er Mo dule Bo ard
R e m o v i n g a n d I n s t a l l i n g a S e r v e r M o d u l e
server module handle
server module