Avue G40 Kullanıcı Kılavuzu - Sayfa 7

Güvenlik Kamerası Avue G40 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Avue G40 14 sayfaları. Middle speed dome camera series

5.OPERATING THE SPEED DOME

Initial Screen
After powering up, the camera will enter into
FIRMWARE
V1.03
the self-test mode and display the status
Protocol: PELCO
screen (see picture left). It contains
Dome Address: 001
information about the model and current
Comm 9600,N,8,1
settings.
- "
FIRMWARE
": Model number
- V1.03: Current firmware version
- Protocol: Control protocol which currently used
- Dome address: Address ID of speed dome. Please refer to the section "Protocol
setup " for details
- Comm 9600,N,8,1: Current setting of the serial communication interface
9600: Baud rate. Please refer to section "Baud-Rate setup" for details
N, 8, 1: No parity bit, 8 bit length, 1 stop bit. This setting cannot be changed
The intial screen will remain on until any user action is taken. If the power-up action is
set, the initial info wil vanish immediately.
Operation Screen
The operation screen can display additional
information.
Temperature: Current temperature inside the speed
dome( °C)
Cam title:
User definable camera title
Zone:
Current zone name
Pan deg.:
Pan angle, 0-359°
Tilt deg.:
Tilt angle, 0-90°
Zoom Factor: Zoom factor
Display of the information can be activated or
deactivated through the OSD menu.Pplease refer to
the system setting for detais.
PTZ operation
For the surveillance operation, the dome can be controlled from a keyboard device,
Multiplexer or DVR through RS485 interface. Make sure that the cable is connected
and the settings (baud rate, Address ID and protocol) of both, keyboard and the dome,
are correctly configurated. For further details on operating the PTZ, please refer to the
user's manual of the keyboard.
9
Some products may not be available in your country, please contact our distributor for more details
Temperature
CAM TITLE
32.0
ZONE-1
285 78
18X
Zoom factor
Tilt degree
Pan degree
Zone description

6.OSD

OSD Menu
The dome camera are equipped with the new OSD Menu function. All operational functions
and camera related settings can be controlled here. In order to use the OSD function, a
telemetric controller device, such as keyboard, DVR or other devices with similiar functions,
is required. Please make sure that the device used is properly physically connected to the
dome and all connection parameters are set.
How to start the OSD Menu
To start the OSD Menu, you need to press the following sequence on the keyboard:
call
9
5
With
keyboard
9
5
Shot
With keyboard
(
3-Axis
)
In case a DVR is used for operating the OSD, select "go to preset 95" or 2 X "go to preset 9".
Please refer to the DVR's operation manual for more details.
Note that in some situations, it is not possible to access the OSD menu:
1. The dome is running a tour
2. Performing PTZ operations
3. Dome is receiving a command other than OSD-request from the keyboard
To solve this inability stop the operation and try again.
Main menu and navigation
After entering the OSD Menu, the screen will show
menu items . Use the controller's joystick to navigate
Main Menu
the menu's main and sub items by moving in the
desired direction. The angle mark on the beginning of
SYSTEM SETTING
every item indicates the selection.
CAMERA SETTING
FUNCTION SETTING
UP, DOWN:
WINDOW BLANKING
ALARM
RIGHT:
EXIT
to
LEFT:
For more inforamtion, please refer to the illustration on
Symbols and indicator
Cursor.
Sub item is selected. use up or down to change value
This item has subitem(s)
Some products may not be available in your country, please contact our distributor for more details
call
9
2 X
Enter
Enter
or
2 X
9
Enter
Enter
Shot
or
- Moving between current menu items
- Changing the value in sub items
- Enter the selected menu item
- Confirm the value change and return
item selection
- Exit from sub menu
10