Miller ArcReach SuitCase Non-CE Kullanıcı El Kitabı - Sayfa 29

Kaynak Sistemi Miller ArcReach SuitCase Non-CE için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Miller ArcReach SuitCase Non-CE 48 sayfaları.

Miller ArcReach SuitCase Non-CE Kullanıcı El Kitabı

5-12. Motor Board (PC1) DIP Switch Settings

Complete Parts List is available at www.MillerWelds.com
1
2
RC111
3
Ref. 247678-B
1 Motor Control Board PC1
2 DIP Switch SW1
3 LED5
DIP switch SW1 is used to match the
performance of PC1 to the characteris-
tics of the motor used in the feeder.
Setting SW1 as shown will help insure
that PC1 and motor are matched for
optimal performance.
If protective coating is present, remove be-
fore setting DIP switch. It is not necessary to
reapply the protective coating.
Set switch positions 1 and 2 so the de-
pressed section of both tabs are toward 1
and 2 as labeled on the switch. As shown in
illustration.
When feeder is powered up, LED 5 on the
motor control board will blink four times. This
blinking indicates everything is working prop-
erly and the DIP switch is set correctly.
After LED 5 is done blinking, it will be either
red or green. Red indicates that the feeder is
connected with electrode positive. Green in-
dicates feeder is connected with electrode
negative.
OM-278792 Page 23