Miller Axcess 300 Kullanıcı El Kitabı - Sayfa 14

Kaynak Sistemi Miller Axcess 300 için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Miller Axcess 300 48 sayfaları. Arc welding power source and wire feeder with meters
Ayrıca Miller Axcess 300 için: Kullanıcı El Kitabı (36 sayfalar), Kullanıcı El Kitabı (44 sayfalar)

Miller Axcess 300 Kullanıcı El Kitabı

3-3. Duty Cycle And Overheating

100% Duty Cycle At 225 Amperes
Continuous Welding
Overheating

3-4. Volt-Ampere Curves

8 0
7 0
6 0
5 0
4 0
3 0
2 0
1 0
0
0
1 0 0
OM-216 967 Page 10
0
15
Minutes
CV MODE
20 0
3 0 0
40 0
A M P E R A G E
60% Duty Cycle At 300 Amperes
6 Minutes Welding
OR
Reduce Duty Cycle
5 00
6 00
Duty Cycle is percentage of 10
minutes that unit can weld at rated
load without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before welding.
Y Exceeding duty cycle can
damage
unit
and
void
warranty.
4 Minutes Resting
A/V
duty1 4/95 − 178 651
Volt-ampere curves show minimum
and
maximum
voltage
amperage output capabilities of
unit. Curves of other settings fall
between curves shown.
.
This
volt-ampere
curve
represents the dynamic output
of the unit with a static load.
va_curve1 4/95
and