4-2. Drive Roll Removal/Installation

Tools Needed:
1
4
3
2
1
Drive Roll Removal Tool
P/N 215676
2
Drive Roll
3
Idler Roll
4
Cam Lever
.
The gun handles do not need
to be removed for access to
the drive or idler rolls.
Drive Roll Removal/Installation
.
For insulated drive roll kits see
Section 8 Options and Acces-
sories.
Pull cam lever away from idler roll.
This relieves pressure against the
the drive roll.
Align drive roll removal tool over
the flats of the drive roll as shown.
Hold the gun with one hand or on a
table top, with the other hand give
the removal tool a quick snap-turn
clockwise direction.
Once the drive roll is loose, contin-
ue to spin drive roll in the clockwise
direction to remove the drive roll
from the gun.
Install a new drive roll on the left-
hand threaded shaft. The drive roll
will self-tighten when it is feeding
wire.
Close top cover.
803 871-A / 803 872-A