Miller Axcess 675 Kullanıcı El Kitabı - Sayfa 34
Kaynak Aksesuarları Miller Axcess 675 için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Miller Axcess 675 48 sayfaları. Automatic welding interface and arc welding power source
Ayrıca Miller Axcess 675 için: Kullanıcı El Kitabı (48 sayfalar)
9-2. Process Control Module PC4 Diagnostic LEDs
9-3. Diagnostic LEDs On Process Control Module PC4
LED
Status
1
On
Off
2
On
Off
3,4
On
Off
OM-217 751 Page 30
Indicates −25 volts DC is present on process control module PC4
Indicates −25 volts DC is not present on process control module PC4
Indicates +25 volts DC is present on process control module PC4
Indicates +25 volts DC is not present on process control module PC4
See Network Status Table in Section 9-4
See Network Status Table in Section 9-4
1
Process Control Module PC4
Diagnostic LEDs are visible inside unit,
1
located on PC4 mounted on the top tray.
Refer to Section 9-3 for information on
diagnostic LEDs.
Reinstall cover after checking diagnostic
LED1
LEDs.
LED2
LED3
LED4
Diagnosis
216 956-A / Ref. 803 825-A