Miller 1014 Operatör El Kitabı - Sayfa 11
Kamera Aksesuarları Miller 1014 için çevrimiçi göz atın veya pdf Operatör El Kitabı indirin. Miller 1014 12 sayfaları. Arrow series fluid head with euro camera platform
ILLUMINATION BUTTON
BATTERY
BATTERY DOOR
FIG 7
RETAINING SCREW
7 BATTERY REPLACEMENT
The Arrow illumination feature uses a standard long–life
alkaline 12v battery. Under most operating conditions the
battery will provide two years of operation.
Miller approves use of the following batteries: Duracell MN21,
Eveready A23, Vinnic L 1028. Other GP23A batteries also fit.
To change the BATTERY:
7.1 Unscrew the two battery door RETAINING SCREWS and
remove the BATTERY DOOR.
7.2 Remove the BATTERY.
7.3 Insert a new battery, negative end (-) first
7.4 Replace BATTERY DOOR and RETAINING SCREWS.
7.5 Press the ILLUMINATION BUTTON to test operation.
CLEANING
WARNING: Do not immerse in any liquid.
WARNING: Do not use stiff brushes, abrasives, or solvents.
Arrow heads feature protective coatings, dust and moisture
seals and anti-corrosive fittings to ensure long and trouble free
operation, even in harsh environments. To ensure optimum
performance through the life of the head Miller recommends
basic routine maintenance.
When Arrow heads have been used in harsh environments
(such as sand, mud or salt water spray), wipe over with a soft
damp cloth as soon as possible. Use a soft brush to clean
crevices. Remove and clean CAMERA PLATE.
11