HP StorageWorks Core Switch 2/64 Yayın Notu - Sayfa 24
Anahtar HP StorageWorks Core Switch 2/64 için çevrimiçi göz atın veya pdf Yayın Notu indirin. HP StorageWorks Core Switch 2/64 24 sayfaları. Director power cord advisory instruction
Ayrıca HP StorageWorks Core Switch 2/64 için: Quickspecs (13 sayfalar), Yayın Notu (27 sayfalar), Yayın Notu (20 sayfalar), Yayın Notu (13 sayfalar), Yayın Notu (11 sayfalar), Talimatlar (1 sayfalar)
![HP StorageWorks Core Switch 2/64 Yayın Notu](/uploads/products/server2/3836569/3836569.png)
Known Issues
Erroneous Error Message When No Firmware File Selected
During a firmware upgrade, if the Download firmware file from field is left
blank, or erroneous text is entered in the field, the following error message
displays when you click Send and Load Firmware:
System File Error Firmware Successfully Loaded
Although the error message indicates that the firmware has been successfully
loaded, no changes were actually made to the switch or its firmware.
Workaround
Perform the firmware upgrade again, ensuring that the Download firmware from
file field contains a valid file name.
A Device Cannot Send Frames to Itself After the Active Zone Set Is
Deactivated
With the introduction of Hard Zoning in firmware 05.xx.xx, a device can no
longer send frames to itself after the active zone set (of which it is a member) is
deactivated.
Workaround
Perform a block/unblock to the port of the device experiencing this issue to cause
the device to log back in to the fabric and allow the device to send frames to itself.
False SBAR Failure in Director 2/64 Under Very High Fibre Channel
Traffic
In a Director 2/64, a false event 602 and 604 (active SBAR failure) may occur in a
very high traffic environment. The director fails over to the backup SBAR, and no
interruption of fabric operations is encountered.
Workaround
If an event 602 and 604 occur in a Director 2/64 and coincide with very high fibre
channel traffic, remove and replace the SBAR unit and verify the events do not
recur. If the events recur, then the SBAR is defective and must be replaced.
24
Director Release Notes