aquatherm AT600 İşletme Sahibi Kullanım Kılavuzu - Sayfa 10

Isı Pompası aquatherm AT600 için çevrimiçi göz atın veya pdf İşletme Sahibi Kullanım Kılavuzu indirin. aquatherm AT600 12 sayfaları. Swimming pool & spa heat pumps
Ayrıca aquatherm AT600 için: İşletme Sahibi Kullanım Kılavuzu (12 sayfalar), Kurulum Kılavuzu (16 sayfalar)

Freezing Condition Precautions
In areas where extended freezing conditions exist, the heater must be plumbed
as shown here (and the installation manual), so
it can be winterized. Water left inside the heater
will freeze and cause damage.
This plumbing setup will allow the use of
pressurized air to clear the heat exchanger of
water in preparation for an extended freeze. This
should be done as part of your end of swimming
season winterizing.
In warmer southern climates where freezing
conditions are temporary, you should run the
water pump 24 hours a day to prevent the water
from freezing inside the heater. Freeze damage
is not covered and may void the warranty.
Owner Maintenance & Cleaning
1. The heat pump will produce condensation water run off while in operation.
Make sure the condensation drains in the bottom of the heater cabinet do not
become blocked with debris. The condensation run off may attract increased
plant growth and insects in the heat pump area, be sure to keep all plants trimmed
back and treat for insects as needed.
2. The outer air coil (located on three sides of the heater), should be kept free of
debris and buildup. A minimal air coil cleaning should be done as needed and at
least two times per year. If the heater is installed in a sandy or salty condition,
the air coil should be cleaned more frequently.
3. To clean the air coil SHUT OFF ALL POWER, then use a garden hose at low
pressure, (without a pressure nozzle) to lightly rinse the air coil in an up and down
motion. You can use a mild soap while rinsing to help neutralize and clean. DO
NOT spray water directly in heater at high pressure.
4. Cabinet surfaces can be wiped clean with a towel and mild cleaner.
Professional Maintenance
The heater should be serviced regularly like any other machine. A factory au-
thorized, licensed air conditioning or mechanical contractor should perform the
following maintenance procedures periodically.
Contact the
1. Oil the fan motor.
manuafacturer at
2. Check the refrigerant charge.
888-297-3826 for
3. Check the amp. draw.
factory
4. Check all electrical supply connections & breakers.
authorized
5. Clean the air coil with approved solution.
service centers in
6. Clean the interior cabinet bottom of debris.
your area.
7. Spray internal components with lubricant.
8. Inspect the installation including chemical feeder placement.
9. Inspect sprinklers to be sure the heater is not being sprayed.
10. Inspect for insect nests in and around the heat pump and treat.
Page 10