Interrupt Status Register

The interrupt status register indicates the status of each port's interrupt request line. It operates regardless of
whether interrupt sharing is enabled (see below). If two or more ports are sharing the same interrupt level, the
status register will still indicate the correct status of each port's interrupt request line.
Bit No.
7
Name
X
Definitions:
X
Bit not used; generally reads back as a 1
INT2-1
Status of interrupt request for each port:
0 = no interrupt request active for this port
1 = interrupt request active for this port

Default Settings

The default settings for Jupiter-MM-SIO are as follows:
Protocol settings:
Both ports set for RS-232 protocol (Jumpers 2 and 5 installed in locations J7 and J8)
Address/Interrupt settings:
(J9 A B C = In In Out):
Feature
Port 1
Port 2
Interrupt Status

RS-485 Transmitter Control

In an RS-485 network, the same pair of wires is used for both transmit and receive signals. Although any number
of nodes can be listening simultaneously, only one can be transmitting or have its transmitter turned on in order
for valid data to be transmitted across the network. On the Jupiter-MM-SIO, an RS-485 port's transmitter enable
signal is controlled by that port's RTS signal. The RTS signal must be asserted (driven low) to enable the
transmitter and deasserted (driven high) to turn off the transmitter.
Copyright 2001 Diamond Systems Corp.
6
5
4
X
X
X
Address
Interrupt level
100
3
108
3 (shared)
240
3
2
X
X
INT2
Jupiter-MM-SIO User Manual V1.3
1
0
INT1