EASIFLO 1 CHLORINATOR INSPECTION AND MAINTENANCE
Calcium Hypochlorite by the nature of its manufacture contains a small amount of calcium carbonate. Proper water
balance will minimize the buildup of calcium carbonate solids in the EASIFLO 1 Chlorinator, however, periodic
cleaning of chlorinator components is normal and recommended. The following is a list of the parts to be cleaned
and the proper procedures to do so.
TABLE OF CONTENTS
Suggested
Inspection
Section
Frequency
As Needed
Section A:
Section B
As Needed
SECTION A
Cleaning EASIFLO 1 Chlorinator with Hydrochloric Acid
Perform cleaning operation in a well ventilated area. Chlorine gas may evolve causing serious injury or
possible death. Use proper protective equipment per MSDS when handling chemicals. Use caution when
handling feeder parts and solution as they contain chlorine that can bleach clothing or cause injury
Inspection: The solids build-up and cleaning frequency required for the unit will depend on the amount of tablets used
and the pool water chemistry. Described below is the easiest way to remove solids and minor scale buildup using
dilute Hydrochloric Acid.
Maintenance Procedure Steps:
1.
Note the inlet flow setting. Close the inlet and
outlet shutoff valves to the chlorinator.
2.
Lift the Briquette Hopper away from the Discharge
Tank and pour the contents into a clean dry bucket.
Be sure to remove all pieces of briquettes. If
necessary, rinse any heavy solids buildup from the
hopper before proceeding.
3.
Lift out dissolving cup, pour contents into a bucket
and rinse out solids.
4.
Remove briquette grid and place in cup (provided
with system). Fill with 0.25 litres of water. Slowly
pour 0.25 litres of prepared 10 parts water to 1 part
acid into cup. Pour 5 litres of water and
acid solution into discharge tank.
agitation may be required to dissolve solids and
scale. Allow acid to dissolve solids and scale,
evident by the foaming action.
minutes, check for presence of scale on grid. If
Contents
Use of Hydrochloric Acid to remove solids and scale from the Easiflo 1
necessary, add additional acid solution to dissolve
any remaining scale or scrape with putty knife.
5.
Replace the Dissolving Cup in Base.
6.
Pour the contents from the cup with grid into
dissolving cup and allow 10 minutes for scale to
dissolve.
7.
Put the hopper back on the base and the Briquette
grid back into the bottom of the hopper. Rinse the
Briquette grid thoroughly with water.
8.
Pour Easiflo
Briquette Tank.
9.
Open inlet and outlet shut off valves to the
chlorinator. Adjust inlet flow to desired setting.
1/
litre of
2
Frequent
10. Dispose of chlorinated solution from step 2 either
into pool or skimmer.
NOTE:
After 10 to 20
allow briquette hopper to completely empty once per
week.
4
Chlorinator
Troubleshooting Guide
®
Briquettes from bucket back into
To increase the period between cleanings,