Digikeijs DR5033 Kullanım Kılavuzu - Sayfa 8

Genişletici Digikeijs DR5033 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Digikeijs DR5033 18 sayfaları. 3-ampere, h-bridge dcc booster
Ayrıca Digikeijs DR5033 için: Manuel (10 sayfalar), Kullanım Kılavuzu (18 sayfalar)

Digikeijs DR5033 Kullanım Kılavuzu
DR5033 DIGIBOOST

4.0 Connection examples

The connection examples shown here represent only a small part of the possibilities for connecting the DR5033 to different control panels. Please note that
there are of course further possibilities and special cases which cannot be shown here!
4.1 Important notes on using the DR5033.
The configuration is done via LocoNet®.
The DR5033 can be used with control panels that use an H-bridge to generate track signals.
The same voltage must be set on the power supply units of the boosters and control panels.
When using the CDE booster connection on the DR5033, it must be ensured that the CDE connection of the central unit meets the specifications of Fa. Lenz®.
Operation of the DR5033 in conjunction with control panels (e.g. Uhlenbrock®, Piko® Smart ControllerLigth®, etc.) which operate according to the "common
ground principle" is not possible on the same circuit. This can lead to damage to components. Even a busbar separation on both sides is not sufficient! Please
note connection example 4.9.
The tracks must always be separated on both sides between the booster and central areas.
The maximum number of boosters on the Roco® B-Bus® is limited to four.
The transition voltage between the booster ranges must always be less than 0.8 Volt. This can easily be checked with a multimeter (setting the measuring
range to AC alternating voltage). Both rail separations must always be checked. If the value of 0.8 Volt is exceeded, the input voltage of the booster or the
voltage setting of the central unit must be adjusted.
Central
www.digikeijs.com
® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
Stand 2021-07-06
Booster
DR50333
The displayed measured value must not
exceed 0.8 Volt!
Always check both track separations!
P 8