RESETTING YOUR PEDOMETER
Resetting TRIP Memories
Most people prefer to reset counts daily. T o reset your regular
counts (Trip Memories): From STEP , T IME, DISTANCE, or
CALORIE mode, press and hold the yellow RESET button for
at least 2 seconds. Y ou'll see the values all go back to zero.
The T OTAL memories stay as they are when resetting the T RIP
memories.
Resetting TOTAL and TRIP Memories
To reset your T OTAL Memories (which always resets T RIP
Memories) , go into T otal Memory Recall Mode. Press and
hold the yellow RESET button for at least 2 seconds to clear
BOTH TOTAL and TRIP memories.
24
CHANGING STEP FILTER SETTING
While the JW200 PedometerEngine™ Step Sensor is
extremely accurate, some people like to have the ability to
filter out false steps. T herefore, the unit has a variable setting
step filter, to allow fine-tuning to your specific preferences.
You can set the value to any value from 0 – 5 steps. For
example, if the filter is set to "3" , the unit will wait to start
counting steps until more than three steps have been taken in
less than five seconds.
Press S3+ (MODE) or S3– (RESET) to change the Step Filter
Setting.
26
CHANGING UNITS (English vs. Metric)
The Pedometer can display either in English units (in, mi, and lb - this
is the default), or in Metric units (cm, km, and kg). From within Deep
Set mode (see pg. 25), press the S2 (MEMORY) button to cycle back
and forth between setting the Step Filter set point and Choice of Unit
System. T he unit will show either "US" or "EU" (for European Union)
depending on the unit system chosen. If you change units after using
the pedometer, the unit will convert all of your data into the new unit
system when you exit Deep Set model. Y ou can check to see which
system of units you are using by seeing which measurement units
are displayed on the Stride and Weight setting screens.
Press S3+ (MODE) or S3– (RESET) to change the Measurement Mode.
Press and hold S4 (MEMORY) for 2 seconds to exit Deep Set Mode.
Note: T he unit will save any changes and exit set mode after 30
seconds unattended.
28
To replace the battery:
1. Insert a coin into the slot on the
bottom of the case, and twist to
loosen the faceplate. Remove
faceplate and set aside.
2. Locate the battery holder as seen
on sketch. Pull out the old battery,
and push a new LR-44 battery into the holder,
with positive terminal (+) facing up.
3. Snap faceplate back into place, hooking the bottom
two tabs first, then closing by pressing together at the
top two tabs.
30
OTHER SETTINGS
The Step Filter and Unit of Measurement settings are
accessed through a special "deep set" mode.
To enter this mode, press and hold the S1 (MEMORY) button
for 4 seconds. T he screen will display a single digit. From
within Deep Set mode, press the S2 (MEMORY) button to
cycle back and forth between the Step Filter set point and
Choice of Unit System.
"US" (English)
or "EU" (Metric)
STEP TIME
XL
190
M
JW200
S3-
Set measurement mode
REPLACING THE BATTERY AND MASTER RESET
When the display starts to dim or goes blank, it is time to
replace the battery.
If the display is not uniformly dim or blank, and appears to
display "erroneous data" , do a Master Reset by pressing all
3 buttons simultaneously for 3 seconds and then release.
The display should go blank, then turn all segments on, then
display 0 steps in Step Mode.
Note: All the settings will return to their default setting values.
If you need to change the battery, the settings will also revert
to default settings.
SPECIFICATIONS, FEATURES, and FUNCTIONS
Description of Functions
• Counts Steps up to 99,999 then rollover.
• Has a T otal Memory for Steps that counts up to 99,999,999
steps, then rollover.
• Counts T ime spent in step activity, up to 999 Min 59 sec,
Battery
then rollover. Automatically counts whenever step activity
is occurring.
• Has a T otal Memory for Activity T ime that counts up to
99,999 minutes, then rollover.
• Counts distance traveled during step activity, up to
999.99 mi or km, then rollover. Automatically counts
whenever step activity is occurring.
Can be set
STEP TIME
from 0-5
steps
-
D
W
XL
IGI
ALKER
.COM
XL
M
190
DIST CAL
JW200
Set Step Filter set point
S1,S2,S4
S3+
25
-
D
W
XL
IGI
ALKER
.COM
DIST CAL
S3-
S1,S2,S4
S3+
27
29
31