INSTALLATION
Once the unit has been removed from its shipping container, it should be inspected for damage that may have
occurred while in transit. Immediately notify the carrier if any damage is found.
1. Provide minimum clearances as per table below.
2. Position kettle in its designated area. Note: When positioning kettle, do not use the plumbing connections.
Anchor the unit securely
3. NSF standards require the base on the to be sealed to the table top to prevent seepage from accumulating
under the unit. Use a good grade of silicone sealant.
Model Number
TT-TT2/3J-T-E20QT &
TT-TT2/3J-T-E40QT
Electrical Connection
Check the electrical requirements of your unit as listed on the nameplate to be sure that your available power supply
line is capable of powering the unit properly. A junction box is provided for connecting the power supply line to the
unit. It is advised, and most electrical codes require, that an electrical cutoff device, such as a fused disconnect
switch or equivalent, be installed in the power supply line between the main and the kettle. All electrical connections
must be in accordance with all applicable electrical codes. The electrical wiring diagram is located inside the control
housing.
Caution: Kettle must be electrically grounded for safe operation. For proper grounding procedures see local codes
or, in the absence of local codes, the National Electrical Code ANSI/NFPA 70-1993 (latest edition).
Water Fill Instructions
Refer to illustrated figure.
Warning! After start-up use pure distilled water (free of chlorides) only. Do not use tap water to refill to correct
water level.
exceeds the minimum level. DO NOT FILL BEYOND THE MAXIMUM LEVEL.
6. Remove funnel, replace pipe plug and secure tightly and restore power to the kettle.
Back of Unit Clearance
11.0" (minimum)
Kettle Capacity
Gallon of Pure Distilled Water Charge (Quarts)
1.
Allow kettle to cool. Never attempt to add
water to a hot kettle.
2.
Lift the safety valve lever to release any
residual steam contained in the steam jacket.
3.
Place the thermostat in the off position.
Disconnect power at the customer supplied
electrical cut-off device.
4.
Remove pipe plug and place a funnel in
the inlet elbow. (See illustration at left).
5.
Pour water into funnel. Lift safety valve
lever to allow air to escape from the jacket.
Continue adding water until water in the jacket
20qt./5 gal
40qt./10 gal.
11
Sides of Unit Clearance
15.00"
15
2