NO.
Set value
Grid High
1
480
–480V
2
505
–505V
3
530
–530V
4
555
–555V
5
580
–580V
6
605
–605V
7
630
–630V
8
655
–655V
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
8-12
Purpose
Adjustment/Operation test/check
Function
Used to check and adjust the operation of the main
(Purpose)
charger grid voltage (low mode) in each printer mode
and the control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
The input value is in the increment of –25V.
(Initial screen)
(Input/Selection screen) (Executing screen)
Sim8-12 MHV(L) PRT
Sim8-12 MHV(L) PRT
1:DENS1(600)
3
5:DENS5(600)
2:DENS2(600)
5
3:DENS3(600)
5
1/4
EXEC [ 1- 8]
Display items
Content
Density 1 (600dpi)
1:DENS1(600)
Density 2 (600dpi)
2:DENS2(600)
Density 3 (600dpi)
3:DENS3(600)
Density 4 (600dpi)
4:DENS4(600)
Density 5 (600dpi)
5:DENS5(600)
Toner save (600dpi)
6:TS(600)
Density 1 (1200dpi)
7:DENS1(1200)
Density 2 (1200dpi)
8:DENS2(1200)
Density 3 (1200dpi)
9:DENS3(1200)
Density 4 (1200dpi)
10:DENS4(1200)
Density 5 (1200dpi)
11:DENS5(1200)
NO.
Set value
Grid High
1
480
–480V
2
505
–505V
3
530
–530V
4
555
–555V
5
580
–580V
6
605
–605V
7
630
–630V
8
655
–655V
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
Grid Low
–350V
–375V
–400V
–425V
–450V
–475V
–500V
–525V
Sim8-12 MHV(L) PRT
7
5:DENS5(600)
7
EXEC
[ 1- 8]
Installation
Default
range
1-8
5 (–450V)
5 (–450V)
5 (–450V)
5 (–450V)
7 (–500V)
3 (–400V)
Disabled
Disabled
Disabled
Disabled
Disabled
Grid Low
–350V
–375V
–400V
–425V
–450V
–475V
–500V
–525V
AR-M208 SIMULATION 8 - 4
9
9-1
Purpose
Operation test/check
Function
Used to check and adjust the operation of the load
(Purpose)
(motor) in the duplex section and the control circuit.
Section
Duplex
Item
Operation
Operation/procedure
Select with the 10-key and operate for 30 seconds.
(Initial screen)
Sim9-1 MOTOR CHECK
1:DMF600 4:DMR1200
2:DMF1200
3:DMR600
EXEC
2
Duplex motor forward rotation (600dpi)
1:DMF600
Duplex motor forward rotation (1200dpi)
2:DMF1200
Duplex motor reverse rotation (600dpi)
3:DMR600
Duplex motor reverse rotation (1200dpi)
4:DMR1200
9-5
Purpose
Adjustment
Function
Used to adjust the switch back time of the duplex
(Purpose)
motor.
Operation/procedure
Set the switch back time of the duplex motor.
(Initial screen)
Sim9-5 SW BACK TIME
1:600dpi
50
7
2:1200dpi
50
1
7
Display items
Installation range
1:600dpi
2:1200dpi
21
21-1
Purpose
Setting
Function
Used to set the maintenance cycle.
(Purpose)
Item
Specifications
Operation/procedure
Enter the adjustment value and press the [OK] key.
Sim21-1 CYCLE SET.
MAINTE CYCLE
0
(0:5 1:10 2:20 3:25
4:50 5:80K 6:FREE)
[ 0- 6]
0
Item
Content
0
5K (5000 sheets)
1
10K (10000 sheets)
2
20K (20000 sheets)
3
25K (25000 sheets)
4
50K (50000 sheets)
5
80K (80000 sheets)
6
FREE
(Executing screen)
Sim9-1 MOTOR CHECK
1:DMF600 4:DMR1200
2:DMF1200
3:DMR600
EXEC
2
(Input screen)
Sim9-5 SW BACK TIME
1:600dpi
50
[ 18- 76]
50
Default
18-76
50
Disabled
Counter
Setting range
Default
0-6
Disabled
Disabled
4