Digital Equipment Prioris XL 5166 Kurulum Kılavuzu - Sayfa 16
Sunucu Digital Equipment Prioris XL 5166 için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Digital Equipment Prioris XL 5166 17 sayfaları. Cpu powergrade kit
Prioris XL and XLDP Server Powergrade Kit
Install the New Medallion
Install the new medallion (product nameplate) to identify your server to service
personnel. To replace the nameplate:
1. Remove the tape on the back to expose the adhesive surface.
2. Press the new nameplate into place over the previous nameplate.
Replace the Panel and Reconnect the Cables
1. Install the left side panel and lock the server.
NOTE:
removed.
2. Connect the cables, the monitor power cord, and the server power cord to
the back of the server.
Run the System Configuration Utility (SCU)
The SCU enables you to check or change your server's configuration. Run
the SCU to configure your server for the new CPU chip or module.
To start and run the SCU:
1. Insert the SCU diskette into drive A and turn on your server. The diskette
should boot automatically from the diskette.
2. When the SCU title appears, press any key to continue. Afterwards,
follow the instructions on your screen to access the SCU main menu.
3. From the main menu, press the up or down arrow to highlight an item and
then press Enter to select it. Press F1 at any time for help about a
selection.
4. From the main menu select Configure Computer and then View
and Edit Details. Example:
If you installed a video option card, select the Advanced Control
Group and disable the Embedded - PCI VGA controller.
12
The server will not power up with the side panel