Ricoh J2SS Teknik Bülten - Sayfa 11
Yazıcı Ricoh J2SS için çevrimiçi göz atın veya pdf Teknik Bülten indirin. Ricoh J2SS 17 sayfaları.
Model:
J2SS
Subject:
Software Change
From:
QAC Field Information Dept.
Classification:
The software in the ROM on the main board has been changed to meet the Energy Star
requirements.
The possible range of Auto Shut-off Time settings in SP mode #15 (which was added by
RTB #3) has been expanded as follows:
Mode No.
15
Auto Shut-off Time
Setting
(115 V machines only)
The suffixes of the ROM and the main board have been changed as follows:
Description
ROM
Main Board
Note: The suffix changes have been applied not only to the 115 V machines but also to the
other machines.
Note: Please refer to MB #20 for the cut-in serial numbers.
T
echnical
Troubleshooting
Mechanical
Paper path
Other (To meet Energy Star Standards)
1 to 120 minutes
(1 minute per step)
Default: 30 minutes
Part Number
A1635208
A1635230
B
ulletin
Date:
15-Dec-97
Prepared by:
Part information
Electrical
Transmit/receive
Old Range
Old Suffix
No suffix
A
PAGE: 1/1
No:
07
A. Sasaki
Action required
Service manual revision
Retrofit information
New Range
1 to 240 minutes
(1 minute per step)
Default: 30 minutes
New Suffix
A
B