CAB WICON SQUIX Servis Kılavuzu - Sayfa 14
Endüstriyel Ekipmanlar CAB WICON SQUIX için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. CAB WICON SQUIX 18 sayfaları. Wrap-around applicator
4
Adjustments
14
4.1
Adjusting the Centering Panels
i
Note!
The applicator must be operated with the printer to adjust the centering panels.
Checking
Switch on the system
Insert the calibration rod 10 mm (1 / Part No. 5988543).
Turn the winder plate by pressing the single-step key
If the rod hunting seems to be excessive the centering panels (7) may be adjusted individually.
Fig. 15
Adjusting the centering panels
Adjusting
Remove the side covers.
Caution!
!
Risk of hand injuries
Do not grasp in the area of the turning winder plate!
Loosen two screws (2) and slightly pivot the centering panel (3).
Tighten the screws and repeat the check.
If necessary repeat the adjustment.
Mont the side covers.
2
1 2
3
and observe the hunting of the rod.
14