Argo AW22AL Kullanım Talimatları Kılavuzu - Sayfa 8

Klima Argo AW22AL için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Argo AW22AL 12 sayfaları. Split air conditioner system
Ayrıca Argo AW22AL için: Kullanım Talimatları Kılavuzu (12 sayfalar)

Argo AW22AL Kullanım Talimatları Kılavuzu
NOTE
The air conditioner changes the operation mode (from cool to heat
or vice versa, if one of the following conditions occurs:
- ZONE A: changes if the difference between the room temperature
and the temperature set on the remote control unit is at least 3°C..
- ZONE B: changes if the difference between the room temperature
and the temperature set on the remote control unit is at least 1°C,
one hour after the compressor stop.
- ZONE C: never changes if the difference between the room
temperature and the temperature set on the remote control unit is
no more than 1°C.
EG

DEHUMIDIFYING (DRY)

1. Set the MODE selector switch to "DRY"
2. Press the ON/OFF button and switch the air condioner ON.
3. Press the TEMP. buttons to set the desired temperature (the
temperature range is between 30 °C max. and 16 °C min.).
THE DISPLAY SHOWS THE SELECTED TEMPERATURE.
NOTE
G
Use DRY operation when you want to reduce the humidity in the
room.
G
Once the room temperature reaches the set level, the unit
repeats the cycle of turning on and off automatically.
G
During DRY operation, the fan speed is automatically set to low
or stops to prevent overcooling.
G
Dry operation is not possible if the indoor temperature is 15 °C
or less.

FAN ONLY

If you want to make air circulate without any temperature control,
follow these steps:
1. Set the MODE selector switch to "FAN"
2. Press the ON/OFF button and switch the air conditioner ON.

ADJUSTING THE FAN SPEED

AUTOMATIC
Simply set the FAN SPEED selector to the
. A microcomputer automatically controls the fan speed when the
AUTO mode is selected. When the air conditioner starts operating,
the difference between the room temperature and the set
temperature is detected by the microcomputer which then
automatically switches the fan speed to the most suitable level.
NOTE
In FAN Only mode the fan speed is adjusted automatically as in
cooling mode.
WHEN DIFFERENCE BETWEEN
ROOM TEMPERATURE AND SET
TEMPERATURE IS
Cooling and
dehumidifying modes:
Heating mode:
.
.
FAN SPEED
2 °C and over
High
Between 2 and 1 °C
Medium
Below 1 °C
Low
2 °C and over
High
Below 2 °C
Medium
NOTE
The above mentioned data make reference to the conditioner
operating when the sensor on the remote control unit is ON. (Refer
to temperature sensor selector). If the sensor on the indoor unit
is being used then actual operation will slightly differ from that
described in the above tables. (
control unit display).
MANUAL
If you want to manually adjust speed just set the FAN SPEED
selector as desired.
High speed

SLEEP MODE

G
The SLEEP mode enables you to save energy.
1. Set the MODE selector to cool, dry or heat.
2. Press the SLEEP button.
3. The
mark appears on the display. Press the SLEEP
button again to release the SLEEP function.
What does the SLEEP mode mean?
In this mode, the air conditioner will cool or heat the room to the
set temperature, and then the thermostat will make the unit pause.
After about 1 hour, the air conditioner will automatically reset the
set temperature as follows (also refer to graphs).
OPERATING MODE
Heating
Cooling and Dehumidifying
When the room temperature reaches the new set value, the
thermostat will cause the unit to pause. After about 1 hour the
temperature will be raised by 1 °C in cooling, or lowered by 1 °C
in heating. This enables you to save energy without sacrificing
your comfort.
position
COOLING AND DEHUMIDIFYING
Setting temperature
1°C
1 hour
8
) Sign shown on the remote
Med. speed
SET TEMPERATURE CHANGE
Lowered by 1 °C
Raised by 1 °C
Room temperature
1°C
1 hour
TIME
HEATING
COOL / DRY / HEAT / FAN
Setting temperature
1 C
1 hour
1 hour.
Low speed
Room temperature
1 C
TIME