Cable Electronics CE Labs HSW44C Kullanım Kılavuzu - Sayfa 10
Matris Anahtarlayıcı Cable Electronics CE Labs HSW44C için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Cable Electronics CE Labs HSW44C 13 sayfaları. 4x4 hdmi over cat5 matrix with ir pass-through
SW Main for firmware update (for technical support only)
DIP Switch Position
Normal Operation Mode
6
Firmware Update Mode
7
Note
6. Factory default for SW Main: Pin#1-OFF [ ], Pin#2-OFF[ ],
Pin#3-ON [ ], Pin#4-OFF[ ]. PLEASE MAINTAIN THIS SETTING AT
ANYTIME FOR REGULAR USE!
7. Sequence for firmware update WARNING! [Firmware update
only can be done via RS-232 port and connection to PC set
at COM1)
[1] Power off the HSW44C.
[2] Set the DIP switch position to Firmware Update Mode.
[3] Power on the HSW44C.
[4] Power off the HSW44C.
[5] Set the DIP switch position to Normal Operation Mode.
[6] Power on the HSW44C.
Pin 1
Pin 2
Pin 3
Pin 4
OFF [ ] OFF [ ]
ON [ ]
OFF [ ]
ON [ ]
ON [ ]
OFF [ ]
OFF [ ]
Method C: Software Control through RS-232
1
2
3
4
Setting: Set the ID of this device for cascading or other purposes in
1
the future.
7
6
5
8