e REMOTE connector (8-pin)
For connection to an RM-B150/B750 Remote Control Unit,
RCP-700/900-series Remote Control Panel, or MSU-900/950
Master Setup Unit.
f CAMERA POWER switch and indicator
To turn the power ON/OFF.
ON: Set the switch to the ? side.
OFF: Set the switch to the 1 side.
The indicator lights in green when the power is turned ON.
g DC IN (DC power supply input) connector (XLR 4-pin)
For connection to an AC-DN10 AC Adaptor, etc. to supply
power to the camera.
h "Memory Stick Duo" slot and access lamp
When you insert a "Memory Stick Duo" into the slot, the
access lamp lights in green.
The lamp is lit in red while writing/reading data to/from the
"Memory Stick Duo."
Caution
• Only a "Memory Stick" of Duo size can be used with the
camera.
• When the access lamp is lit in red, do not insert/remove the
"Memory Stick Duo" or turn off the camera.
i "Memory Stick" cap
Remove the cap before inserting a "Memory Stick Duo."
Caution
Do not use excessive force to pull the "Memory Stick" cap.
j
(LAN) connector (RJ-45 type, 8-pin)
To connect to a LAN. Use a LAN cable (shielded, category 5
or above) to connect to the hub of the LAN (10BASE-T/
100BASE-TX).
CAUTION
• For safety, do not connect the connector for peripheral
device wiring that might have excessive voltage to this port.
Follow the instructions for this port.
• When you connect the LAN cable of the unit to peripheral
device, use a shielded-type cable to prevent malfunction due
to radiation noise.
ATTENTION
Par mesure de sécurité, ne raccordez pas le connecteur pour
le câblage de périphériques pouvant avoir une tension
excessive à ce port. Suivez les instructions pour ce port.
VORSICHT
Aus Sicherheitsgründen nicht mit einem Peripheriegerät-
Anschluss verbinden, der zu starke Spannung für diese
Buchse haben könnte. Folgen Sie den Anweisungen für diese
Buchse.
k NETWORK indicator
To indicate the state when connected to a network system.
Lit: Successfully connected to an external control device
(MSU-900 series master setup unit, RCP-900 series
remote control panel, etc.).
Flashing: Unable to connect to an external control device
(MSU-900 series master setup unit, RCP-900 series
remote control panel, etc.) properly.
Off: A LAN cable is not connected or the connection settings
of the network system are not configured.
For details on the adjustment, see "Configuring Control
System Connection Settings" (page 12), "MAINTENANCE
Menu" (page 24), "DIAGNOSIS Menu" (page 28).
l GENLOCK (external sync signal input) connector
(BNC type)
To input an external sync signal (BB or 3-level sync) to
synchronize the camera.
Note
Even when a BB signal is used for the external sync signal, no
subcarrier phase-lock function is available for the VBS output
signal.
m SDI 1 (serial digital interface) connector and SDI 2
connector (BNC type)
For HD-SDI or SD-SDI signal output.
HD-SDI signal and SD-SDI signal output can be selected on
the menu. (It is not possible to select an HD-SDI signal and
SD-SDI signal separately for the SDI 1 connector and SDI 2
connector. One or the other needs to be selected.)
Note
The functions that can be displayed differ depending on the
output settings.
For details on the adjustment, see "Connector Output Settings
and Display Functions" (page 9).
n VBS connector (BNC type)
To output a VBS signal.
Caution
• The VBS output signal has no subcarrier phase-lock
function with respect to external sync signals.
• The functions that can be displayed differ depending on the
output settings.
For details on the adjustment, see "Connector Output Settings
and Display Functions" (page 9).
Connector Output Settings and Display
Functions
The functions that can be displayed differ depending on the
connector output settings.
Connector
Output
name
setting
Setting
Operation
Menus
status
SDI 1
HD/SD No
No
2)
SDI 2
HD
Yes
Yes
2)
SD
Yes
Yes
2)
VBS
SD
Yes
Yes
1) The focus assist functions include the VF DETAIL function and
FOCUS ASSIST INDICATOR function.
2) Linked to the DISPLAY/MENU switch setting.
3) A function can be set to ON/OFF on the OPERATION menu.
Display functions
Marker
Zebra
Focus
1)
assist
No
No
No
2)
3)
3)
3)
Yes
Yes
Yes
2)
No
No
No
2)
No
No
No