Digitrax BDL16 Kurulum Bilgileri - Sayfa 7
Güvenlik Sensörleri Digitrax BDL16 için çevrimiçi göz atın veya pdf Kurulum Bilgileri indirin. Digitrax BDL16 10 sayfaları. Loconet occupancy detector with rx4
Figure 3: Reverse Section Wiring
PS12
12 VAC
LocoNet
Power
to other LocoNet
Devices such as
Supply
(Throttles, Boosters,
UP3's Etc.)
External LED
Connectors (pin 1)
See Fig. 4
All 4 Detection Sections
A
in this zone can only be
B
used in this
D
reverse section
C
These 2 wires come
from a reversing device
such as a PM4 Reverse
Section, a separate
auto-reversing booster,
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
a DPDT toggle switch,
or other reversing
device.
Reverse
Section
Using 4
Detection Sections
Option LED (red)
ID LED (green)
AUX1
BDL16
Top View
AUX2
TOP ROW
Booster Ground to pin 11
Zone Common
For non-reversing Detection
Sections
Detection Common
For non-reversing
Detection Sections
Non-reversing
part of layout
12
8.0 Auto-Reversing
Note that an auto-reverse section can only use detection sections that are con-
tained in a BDL16 zone that is correctly set up for auto-reversing , see Figure
3: Reverse Section Wiring for a wiring example.
9.0 LED Occupancy Indicators
9.1 LT5 Tester
Each BDL16 comes with an LT5 that will help you with layout wiring and
troubleshooting for transponding & detection with Digitrax BDL16 LocoNet
Occupancy Detector. The LT5 plugs onto the LED Connections of BDL16 and
the LEDS on the LT5 light when detection sections are occupied. The status of
power to each zone is also shown.
LT5 Tester
LED for First Detection Section (1,5,9, or 13)
LED for Second Detection Section (2,6, 0, or 14)
LED for Third Detection Section (3,7,11, or 15)
LED for Fourth Detection Section (4,8,12, or 16)
LED for Power Zone (A, B, C, or D)
Socket
LocoNet
Connectors
LT5 Tester
Plug LT5 Tester in to External LED Connectors A,B,C, or D
with LED's facing the edge of the BDL16 as shown.
BDL16 (Partial Top View)
9.2 Panel Indicator Wiring
For a front panel display of status with user supplied LED's, connect to the
four 0.1" 2x5 headers, and wire up LEDs as shown in Figure 4: LED Panel
Indicators Wiring. DigiKey (1-800-DigiKey) part number M1AXA-1036R-
ND is a convenient plug and cable assembly that you can use to wire LED
indicators. Header "A" includes the 4 detection indicators for detection sec-
tions 1 to 4 and the zone power indicator for zone A that includes these four
External LED
DS 8
Connectors
DS 7
DS 6
DS 5
Zone B
DS 4
DS 3
DS 2
DS 1
Zone A
13