Figure 11
Close the socket latch. See
Step 2
Lock the socket latch into place with the hook. See
Step 3
Using the tube of thermal compound provided with replacement CPUs and servers (Dow-Corning
Step 4
TC-1996, Intel D54816-0 or an equivalent may also be used), add a protective film of thermal compound
to the bottom of the heat sink where it will contact the CPU. See
Replace the heat sink (N20-BHTS1). See
Step 5
Caution
For proper cooling, align the arrows on the installed heat sink to point to the front and back of the blade.
Make sure that the heat sink fins are aligned to run along the length of the blade server (see
Secure the heat sink to the motherboard by tightening the four captive screws. See
Step 6
Installing Memory
To install a DIMM into the B200 blade server, follow these steps:
Open both DIMM connector latches.
Step 1
OL-22473-02
Inserting the CPU and Replacing the Heat Sink
5
6
6
6
1
3
2
Figure
11, callout 2.
4
6
Figure
11, callout 3.
Figure
11, callout 5.
Cisco UCS B200 Blade Server Installation and Service Note
Removing a Blade Server Cover
Figure
11, callout 4.
Figure
11, callout 6.
Figure
11).
21