Cisco UCS B200 M4 Servis Kılavuzu - Sayfa 19
Sunucu Cisco UCS B200 M4 için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Cisco UCS B200 M4 24 sayfaları. For e5-2600 v4 series cpus
Ayrıca Cisco UCS B200 M4 için: Kurulum ve Servis Notu (30 sayfalar), Kurulum ve Servis Notu (46 sayfalar), Yükseltme Kılavuzu (9 sayfalar)
Servicing a Blade Server
information, see the firmware management chapter of one of the Cisco UCS Manager software configuration
guides.
Procedure
Step 1
Position the adapter board connector above the motherboard connector and align the two adapter captive
screws to the standoff posts on the motherboard.
Step 2
Firmly press the adapter connector into the motherboard connector (callout 2).
Step 3
Tighten the two captive screws (callout 3).
Tip
Figure 16: Installing an Adapter Card
Installing the NVIDIA M6 GPU Adapter Card
The NVIDIA M6 graphics processing unit (GPU) adapter card provides graphics and computing capabilities
to the server. If you are installing the NVIDIA GPU to a B200 M4 in the field, the option kit comes with the
GPU itself (CPU and heat sink), a T-shaped installation wrench, and a custom standoff to support and attach
the GPU on the B200 M4 motherboard. See the three components of the option kit in the following figure:
Removing an adapter card is the reverse of installing it. You might find it helpful when removing
the connector from the motherboard to gently rock the board along the length of the connector until
it loosens.
Installing the NVIDIA M6 GPU Adapter Card
Servicing a Blade Server
19