Cisco UCS C220 M3 Yapılandırma Kılavuzu - Sayfa 20
Sunucu Cisco UCS C220 M3 için çevrimiçi göz atın veya pdf Yapılandırma Kılavuzu indirin. Cisco UCS C220 M3 33 sayfaları. Security manager 4.3
Ayrıca Cisco UCS C220 M3 için: Hızlı Başlangıç Kılavuzu (29 sayfalar), Yükseltme Kılavuzu (10 sayfalar), Hızlı Başlangıç Kılavuzu (12 sayfalar)
Table 9.
RAID
level
00
10
50
60
To create a RAID volume based on multiple drive groups (RAID 00, 10, 50, or 60), follow the steps presented here.
Step 1: Log in to Cisco IMC.
Step 2: Open the Storage tab and click on the Controller Info tab. Select the Create Virtual Drive from Unused
Physical Drives option; then proceed with virtual drive creation.
© 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public.
RAID 00, 10, 50, and 60 Configuration
Description
Configure RAID 00 by spanning two contiguous RAID 0 virtual drives, up to the maximum number of supported devices for the
controller
Configure RAID 10 by spanning two contiguous RAID 1 virtual drives, up to maximum number of supported devices for the
controller RAID 10 supports a maximum of eight spans. You must use an even number of drives in each RAID virtual drive in the
span. The RAID 1 virtual drives must have the same stripe size.
Configure RAID 50 by spanning two contiguous RAID 5 virtual drives. The RAID 5 virtual drives must have the same stripe size.
Configure RAID 60 by spanning two contiguous RAID 6 virtual drives.
Page 20 of 33