11 Specifications
Detection Method
Microwave Frequency
Power Input
Current Draw
Temp Compensation
Alarm Period
Alarm Outputs
Tamper Switch(s)
Warm up Period
LED Indicator
RF Immunity
Electrostatic Immunity
Transient Immunity
Operation Temp
Dimensions
Weight
European directives
European standards
requirements:
USA & Canada
Protection Degree
•
Specifications are subject to change without prior notice.
PIR AND MW
24.125 GHz
9.6 to
16Vdc
Active:
24mA (±5%)
Standby: 21mA (±5%)
Yes, Dual slop temperature compensation
2 sec (±0.5sec)
Form C (NC, NO, Common)
28Vdc 0.1 A with 10 Ohm
Two Switches
N.C 28Vdc 0.1 A with 10 Ohm Series protection resistors
Opens when cover is removed from unit's base
30sec (± 5sec)
All LED's are ON during ALARM
10 V/m plus 80% AM from 80 MHz to 2GHz
6kV contact, 8kV air
1kV
-10ºC ~ +50ºC (14°F ~ 122°F)
175mm x 70mm x 45mm (6.9" x 2.8" X 1.8")
210gr. (0.5 lbs)
RTTE directive:1999/5/EC
EMC directive: 89/336/EEC
Low Voltage directive: 73/23/EEC
RoHS directive: 2002/95/EC
EN300 440-2
EN301 489-1
EN50130-4 +A1 +A2
EN61000-6-3+A11
EN60950-1
EN50131-1 / EN50131-2-4 / EN50130-5
47CFR part 15, subpart C, section 15.245
47CFR part 15, subpart
RSS210
ICES-003
IEC 60529: IP 65