10 Test procedure

Walk Test
Make sure LED's control is set to "ON"
Allow 30 seconds of warm up time.
Make sure that the protected area is cleared of all people.
Start walking across the detection zone.
Look at the LED's whenever motion is detected - all LED's are turned ON.
Allow 5 sec. between each test for the detector to stabilize.
Upon installation, the unit should be thoroughly tested to verify proper operation.
Walk across the entire area where coverage is desired. Should the coverage be incomplete,
readjust sensitivity or relocate the detector.
Once coverage is as desired the LED's may be disabled.
NOTE: Walk Test procedure should be conducted, at least once a year, to confirm
proper operation and coverage of the detector.
16