Maintenance
• Periodically check inside evaporator fins and remove any dirt, hair and other debris. this can be removed
using a combination of a soft brush, compressed air, lint brush, and/or a shop vacuum. Caution: do not stick
anything into the evaporator blower- serious injury or death could result. Always wear eye protection when
working around or servicing blower or vents with above methods.
• Check outside condenser fans for proper air flow (air should be felt flowing from a safe distance). Caution:
do not stick anything into the fans- serious injury or death could result. Always wear eye protection when
working around or servicing condenser fans with above methods.
• Outside condenser fins can be cleaned with a pressure washer, hose, or compressed air. Always wear eye
protection when cleaning condenser with above methods.
• Check around inside unit for condensation and check drain tray tubes to make sure they are clear and able
to evacuate condensation.
Troubleshooting
• Unit is not blowing cold air
Solution
:
• Check to make sure manual control has the switch to "On" position or thermostat is set to "Cool".
• Check operation of outside fans, inside blower, and compressor. When initially turned on, the outside
condenser fans and inside evaporator blower will turn on. The compressor will turn on in approximately 30
seconds. To better hear the compressor, turn the evaporator blower to low speed before starting system.
• If you hear all 3 of the above operating, then the system could be low on refrigerant. Have the system
evacuated, checked for leaks, and recharged with appropriate refrigerant based on the installation manual
requirements. Do not add any leak sealants or unapproved leak dyes. Call Cruise N Comfort USA Tech
Support for appropriate leak dye. Leaks in hoses or hose connections can be seen while unit is running by
spraying a soapy water solution onto fitting and checking for bubbles. Leaks may also be evident by
inspecting condenser and hose connections and looking for oil residue.
• If the inside evaporator fan turns on but there is no flow, the evaporator could have iced up due to low air
flow in high humidity conditions and/or is low on refrigerant. Turn unit off for an extended period of time and
run the the blower only mode (on thermostat equipped models). Return to normal operation after unit has
thawed.
• You may also determine if the unit is low on refrigerant by looking for bubbles or liquid in the sight glass on
the receiver dryer. The receiver dryer is a black cylinder with a round sight glass on top located next to the
compressor on HD/MES models. On the VES systems it is inline in between the condenser and the #6
evaporator hose. During operation, bubbles should not be evident after 15 minutes of operation. If the unit
has bubbles, have the system evacuated, checked for leaks, and recharge with appropriate refrigerant based
on the installation manual requirements.
• If outside condenser fans are not turning, turn off unit immediately and check fuses to make sure they are not
blown and check breakers for fault. If this is the case, check the power wire going to fans for a short and
check to see if fans are faulty. Call Cruise N Comfort USA for replacements.
Do Not send Cruise N Comfort units back for repairs before first obtaining an RMA number via
*