Group 2
[1,5]
Group 3
[1,5]
Group 4
[1,5]
5.5 Association Group Info Command Class
5.5.1
Association Group Name Report
Group
Name
Group 1
Lifeline
Group 2
Retransmit
ON/OFF Control(Sensor Probe 1)
Group 3
ON/OFF Control(Sensor Probe 2)
Group 4
5.5.2
Association Group Info Report
Group
Profile
Group 1
General:Lifeline
Group 2
General:NA
Group 3
Notification:WaterAlarm01
Group 4
Notification:WaterAlarm02
5.5.3
Association Group Command List Report
Group
Command Class
Group 1
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_BATTERY
COMMAND_CLASS_SENSOR_MULTILE
VEL
COMMAND_CLASS_NOTIFICATION
COMMAND_CLASS_DEVICE_RESET_LO
CALLY
Group 2
COMMAND_CLASS_CONFIGURATION
Group 3
COMMAND_CLASS_BASIC
Group 4
COMMAND_CLASS_BASIC
5.6 Notification Command Class
Notification Type
Heat Alarm
3.
Single Cast
Send configuration 0x88 report:
Single Cast
Send Basic Set (configured by parameter 0x58) to the associated
nodes in Group 3 when the Sensor probe 1 is triggered.
Single Cast
Send Basic Set (configured by parameter 0x59) to the associated
nodes in Group 4 when the Sensor probe 2 is triggered.
Notification Events
0x04
Previous Events cleared
Overheat detected, unknown Location
water leak.
Send Device Reset Locally when it is reset.
ASSIC Code
4C 69 66 65 6C 69 6E 65
52 65 74 72 61 6E 73 6D 69 74
4F 4E 2F 4F 46 46 20 43 6F 6E 74 72 6F 6C 28 4C 65 61
6B 20 50 72 6F 62 65 20 31 29
4F 4E 2F 4F 46 46 20 43 6F 6E 74 72 6F 6C 28 4C 65 61
6B 20 50 72 6F 62 65 20 32 29
Vg1
01 01 00 00 01 00 00 00
01 02 00 00 00 00 00 00
01 03 00 71 05 00 00 00
01 04 00 71 05 00 00 00
Command
CONFIGURATION_REPORT
BATTERY_REPORT
SENSOR_MULTILEVEL_REPORT
NOTIFICATION_REPORT
DEVICE_RESET_LOCALLY_NOTIFICATION
CONFIGURATION_REPORT
BASIC_SET
BASIC_SET
Page 7
Code
70 06
80 03
31 05
71 05
5A 01
70 06
20 01
20 01
0x00