Exhaust
requirements
Fire/Health
Hazard
l
Do Not use non-metal,
flexible
duct.
l
Do Not use metal duct smaller
than four inches in diameter.
l
Do Not use exhaust
hoods with
metal latches.
l
Check
that exhaust
system is not
longer than specified.
Exhaust
system longer than specified
will:
-
Accumulate
lint.
-
Shorten the life of the dryer.
-
Reduce
the performance,
resulting
in longer drying times
and increased
energy
usage.
Failure to follow specifications
may
result in a fire.
l
Do Not exhaust
dryers into a
chimney,
furnace
cold air duct,
attic or crawl space,
or any other
duct used for venting.
9 Clean the exhaust
system every
other year.
l
Do Not install flexible
duct in
enclosed
walls, ceilings
or floors.
Accumulated
lint could result in a
fire or cause moisture
damage.
. Exhaust dryers outside to prevent
exposure
to substances
in gas
fuels and combustion
which may
be harmful to your health.
The moisture
and lint indoors may
cause:
- FIRE HAZARD from lint collected
in
dryer.
- Moisture
damage
to woodwork,
furniture,
paint, wallpaper,
carpet,
etc.
- Housecleaning
problems
and
possible
health problems.
Failure to follow these instructions
could result in fire damage
or
personal
injury.
Exhaust materials
are not
supplied.
Four-inch
metal exhaust
duct is
required.
Plan installation
to use the
fewest number
of elbows
and turns.
Use duct tape
to seal all joints.
Metal flexible
duct must be fully
extended
and supported
when the
dryers are in final position.
DO NOT
KINK OR CRUSH THE DUCT. The metal
flexible
duct must be completely
open to allow adequate
exhaust
air
to flow.
Allow as much room as possible when
using elbows
or making
turns. Bend
duct gradually
to avoid kinking.
Remove
excess flexible
duct to avoid
sagging
and kinking that may cause
reduced
airflow.
The external
exhaust
ducts can be
routed
straight out the back of the
dryers. Kits are available
to convert
the external
exhaust
duct to be
routed
right, left or through
the
bottom.
See Page 6. Product
dimensions
and recessed
area
requirements
are given on Page 7.
Side or bottom
exhaust:
The maximum
length of the exhaust
system if dryer is
exhausted
out the side or bottom
is 16
feet with two external
elbows
and
hood.
flexible
duct is shown in the chart.
Rear exhaust:
The maximum
length of
the exhaust
system depends
on the
type of duct, the number
of elbows
and the type of exhaust
hood. The
maximum
length for both rigid and
This chart applies
only to individually
,
exhausted
units.
I
EXHAUST HOOD TYPE
MAXIMUM
LENGTH OF 4-INCH
DIAMETER RIGID METAL DUCT
0
43 FT.
41 FT.
36 FT.
1
33 FT.
31 FT.
26 FT.
2
23 FI.
21 FT.
16 FT.
MAXIMUM
LENGTH OF I-INCH
DIAMETER FLEXIBLE METAL DUCT
0
30 FT.
29 FT.
24 FT.
1
24 FT.
23 FT.
18 FT.
2
16 FT.
15 FT.
10 FT.
For exhaust
systems not covered
by
the exhaust
length chart, see
WhirlDool Service
Manual,
"Exhausting
Whirlpool
Dryers," Part No. 603197,
available
from your Whirlpool
parts
distributor.
Service
check:
The back pressure in
any exhaust
system used must not
exceed
0.6 inches of water column
measured
with an inclined
manometer
at the point that the
exhaust
system connects
to the
dryers.
If dryers are installed
in a confined
area such as a bedroom,
bathroom
or closet, they must be exhausted
to
the outside and provision
must be
made
for enough
air for combustion
and ventilation.
(Check
governing
codes and ordinances.
Also refer to
the "Recessed
area and closet
installation
instructions,"
Page 7.)
An exhaust
hood should cap the
exhaust
duct to prevent
exhausted
air from returning
into the dryers. The
outlet hood must be at least 12
inches from the ground
or any object
that may be in the path of the
exhaust.
Four-inch
outlet hood is preferred.
However,
a 2- l/2-inch
outlet exhaust
hood may be used. (A 2-l/2-inch
outlet creates
greater
back pressure
than other hoods.)
A main exhaust
duct can be used for
exhausting
a group of dryers. Main
exhaust
duct should be sized to
remove
200 CFM of air per dryer.
Large-capacity
lint screens of proper
design may be used in the main
exhaust
duct if checked
and
cleaned
frequently.
The room where
the dryers are located
should have
make-up
air equal to or greater
than
the CFM of all the dryers in the room.
Back-draft
damper
kits (Part No.
3391910) are available
from your
Whirlpool
dealer
and should be
installed
in each dryer's exhaust
duct
to prevent
exhausted
air from
returning
into the dryers and to keep
the exhaust
balance
within the main
exhaust
duct. Unobstructed
air
openings
are required.
Each exhaust
duct should enter the
main duct at an angle
pointing
in the
direction
of the airflow.
Ducts
entering
from the opposite
side
should be staggered
to reduce
the
exhausted
air from interfering
with the
other ducts.
The maximum
angle
of each duct
entering
the main duct should be no
more than 30".
Page 5