3°WIRE
DIRECT
WIRE
CONNECTION
Prepare your 3=wire cable for direct connection:
Direct wire cable must have 5 ft. (1.52 m) of extra length
so dryer may be moved if needed.
Strip 31/2' ' (89 mm) of outer
covering from end of cable. Strip
insulation back 1" (25 mm). If
using 3-wire cable with ground
wire, cut bare wire even with outer
covering. Shape wire ends into
hooks.
To connect wires to terminal block,
place hooked end of wire under
terminal block screw, facing to the
right, squeeze hooked end together
and tighten screw.
_18,
Remove
center
screw
Remove center, silver-colored
terminal block screw.
_ ......
9, Connect
neutral
wire
e
Place hooked
end of neutral wire (white or center wire) of direct
wire cable under center terminal
block screw. Squeeze
hooked
end together.
Tighten screw.
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze
hooked ends together and tighten screws. Finally, reinsert tab of
terminal block cover into slot
of dryer rear panel. Secure cover with hold-down
screw. Now,
go to Venting Requirements,
OPTION_
3oWIRE CONNECTION
You must
verify with a qualified
electrician
that this
grounding
method
is
acceptable
before connecting.
21,
Prepare to connect
neutral
ground
wire and neutral
wire
Remove center, silver-colored
terminal block screw. Remove
neutral ground wire from external ground conductor
screw.
and neutral
wire
e
10
Connect neutral ground wire and neutral wire (white or center
wire) of power supply cord or cable under center, silver-colored
terminal block screw. Tighten screw.