Place hooked e nds ofremaining wires u nder o uter t erminal block
screws ( hooks f acing right). Tighten s crews.
24,
Connect external
ground
wit
m
O
Connect external ground wire to the green ground terminal
screw. Finally, reinsert tab of terminal block cover into slot of
dryer rear panel. Secure cover with hold-down screw. Now, go
to Venting Requirements.
¥%NTING
REQUIREMENTS
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent,
Failure to follow these instructions can result in death
or fire.
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT:
Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace,
or a concealed space
of a building. Only rigid or flexible metal vent shall be used for
exhausting.
[] Only a 4" (102 mm) heavy metal exhaust
vent and clamps may be used.
[] Do not use plastic or metal foil vent.
Rigid metal
vent:
[] Recommended
for best drying performance
and to prevent
crushing and kinking.
Flexible
metal
vent:
(Acceptable only if accessible to clean)
[] Must be fully extended and supported
in final dryer location.
[] Remove excess to avoid sagging and kinking that may result
in reduced airflow and poor performance.
[] Do not install in enclosed walls, ceilings, or floors.
[] The total length should not exceed 7 3/4ft. (2.4 m).
NOTE:
If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not plugged
with lint. Replace plastic or metal foil vents with rigid metal or
flexible metal vents. Review Vent system chart and if necessary,
modify existing vent system to achieve best drying performance.
Exhaust
hoods:
[] Must be at least 12" (305 mm) from ground or any object that
may obstruct exhaust (such as flowers, rocks, bushes, or
snow).
B
A
(102m
1_4.4%
(102 ram)
Recommended
styles:
Acceptable
styles:
A. Louvered hood
C. Angled hood
B. Box hood
[] An exhaust hood should cap vent to keep rodents and insects
from entering home.
[] Do not use exhaust hood with a magnetic latch.
11