Xerox Versant 80 Press Müşteri Beklentileri ve Kurulum Kılavuzu - Sayfa 41

Yazıcı Xerox Versant 80 Press için çevrimiçi göz atın veya pdf Müşteri Beklentileri ve Kurulum Kılavuzu indirin. Xerox Versant 80 Press 48 sayfaları. Entry production color presses
Ayrıca Xerox Versant 80 Press için: Güvenlik Kılavuzu (26 sayfalar), Güvenlik Kılavuzu (45 sayfalar)

Xerox Versant 80 Press Müşteri Beklentileri ve Kurulum Kılavuzu
Installation
Optional
Current /
finishing device
run power
1-Tray OHCF
2.5 amps
1.5 amps
Advanced HCF
5 amps
3 amps
Interface Module
1.5 amps
GBC Advanced-
1.2
Punch
amps
High Capacity
0.8 amps
Stacker (HCS)
Standard Finisher
2 amps
Booklet Maker
2 amps
Finisher
SquareFold
0.4 amps
Trimmer Module
2-Knife Trimmer
4 amps
Module
Finisher
1 amps
Module
Finisher
5 amps
Transport
NOTE:
The Standard Finisher Plus requires two NEMA receptacles (NEMA 5-
15R or 5-20R).
Electrical Requirements for the Print Servers
EX 80 Print Server
Print
Current / run
Server
power
Item
EX-I 80
0 to 8 Amperes
controller
180W
100 Watts, 1
Amp (typical)
220 Watts, 2
Amps (max)
EX 80
0.6 to 3
Controller
Amperes
350W
175 Watts, 1.5
Amps (typical)
300 Watts, 2
Amps (max)
Determining the Amp/Circuit Requirements
Use the following formula to determine/calculate the amperage/circuit
requirements for all devices associated with the press; this includes the
Customer Expectation and Installation Guide
Voltage
Power
(VAC)
cord
length
100-120
8.2 feet /
220-240
2.5 meters
100-120
8.2 feet /
220-240
2.5 meters
100-240
8.2 feet /
2.5 meters
100-240
8.2 feet /
2.5 meters
100-240
8.2 feet /
2.5 meters
100-240
8.2 feet /
2.5 meters
100-240
8.2 feet /
2.5 meters
100-240
8.2 feet /
2.5 meters
100-230
14.8 feet /
4.5 meters
100-240
8.2 feet /
2.5 meters
100-240
8.2 feet /
2.5 meters
Voltage
Power cord
Receptacle
(VAC),
length
NEMA part
North
number
America
(NA)
100-240v
7.5
5-15R
47-63 Hz
feet/2.3
meters
100-240
7.5
5-15R
V
feet/2.3
47/63 Hz
meters
Receptacle
Print Server, OHCF, and optional finishing devices.
NEMA part
 
number
NOTE:
This formula does not calculate the press since it is on its own
5-15R or 5-
dedicated circuit.
20R
 
1.
Determine the amps required for each device.
5-15R or 5-
2.
Calculate the total amp sum of all the devices.
20R
3.
The sum total is:
5-15R
12 or below; therefore, a 15 amp circuit may be used with NEMA 5-
15R. However, a 20 amp circuit is recommended using NEMA 5-
5-15R
20R receptacles.
12.1 - 16; a 20 amp circuit is required (NEMA 5-20R receptacles).
5-15R
 
4.
Calculate the total number of devices associated with press,
including the Print Server, OHCF, and all optional finishing devices.
5-15R
This calculation is number of receptacles required. Refer to the
following two examples.
5-15R
Recommended Wall Receptacle Placement
The recommended wall receptacle placement for the print server, OHCF,
5-15R
the press, and its accessories are shown in the following illustration. This is
for USA receptacles only. It is recommended that receptacles be grouped
as shown in relation to the print engine.
5-15R
 
The following illustration shows a full configuration consisting of a
standalone print server, Advanced HCF, the press, Interface Module, GBC
5-15R
AdvancedPunch, High Capacity Stacker, Booklet Maker Finisher with C/Z
Folder, and SquareFold Trimmer Module.
5-15R

Electrical Installation Considerations

Press Electrical Considerations
 Ground Fault Protection is provided which meets Xerox internal safety
requirements and exceeds the Industry Standards for Information
Technology Equipment.
 The electrical outlet must be located within 6 feet (1.83 m) to the right
of the right rear corner of the main processor, or no more than 3 feet
(0.914 m) to the left of the left rear corner of the main processor (when
facing the equipment)
 The power cord must have sole use of the circuit. The outlet/circuit
cannot be shared with any other devices or equipment
 OHCF should be placed within 6 feet (1.83 meters) of wall outlets.
 OHCF have their own power cord and must be plugged into an outlet
separate from the print engine. Ensure that there are enough wall
outlets.
Electrical Considerations for Optional Devices
 Electrical requirements and space requirements must be satisfied prior
to equipment delivery.
 Optional accessories should be placed within 6 feet (1.83 meters) of wall
outlets.
 Most optional devices have their own power cord and must be plugged
into an outlet separate from the print engine. Ensure that there are
enough wall outlets for each required accessory.
Xerox Confidential
Xerox
Versant® ™ 80 Press
®
36