Yamaha PSR-F50 Servis Kılavuzu - Sayfa 17

Elektronik Klavye Yamaha PSR-F50 için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Yamaha PSR-F50 28 sayfaları. Yamaha digital keyboard
Ayrıca Yamaha PSR-F50 için: Kullanıcı El Kitabı (21 sayfalar), Kullanıcı El Kitabı (21 sayfalar), Kullanıcı El Kitabı (21 sayfalar), Kullanıcı El Kitabı (18 sayfalar), Kullanıcı El Kitabı (21 sayfalar), Kullanıcı El Kitabı (4 sayfalar)

Yamaha PSR-F50 Servis Kılavuzu
■ TEST PROGRAM
* If the test number 60 "Factory Set" is executed, the data already set will be lost.
1
Preparations
1) Use an AC adaptor PA-3C or PA-130A.
2) Measuring device: Frequency counter, which can detect thousandth value or more, Level meter (with JIS-C filter), Oscilloscope
* Input impedance of the measuring device should be 1 MΩ or more.
3) Terminal condition:
Use a stereo plug and connect a load resistor of 33 Ω to the [PHONES/OUTPUT] jack for measurement unless
otherwise specified.
4) Controller settings
Initial setting when the power is turned on
2
Starting up the test program
Manual mode
While holding down the keys [C#2], [F2] and [G#2] simultaneously, press the [STANDBY/ON] switch
Auto mode
While holding down the keys [C#3], [F3] and [G#3] simultaneously, press the [STANDBY/ON] switch.
Executed sequentially from [1] to [7] of auto mode test item.
3
Test procedure
Manual mode
1) When the test program is started, " TST " will be displayed on the 7-segment LED.
2) Press the [Tenkey –] or [Tenkey +] button to select a test program item.
3) Press the [START/STOP] button to execute the test.
If the result is OK or test item is completed, press the [START/STOP] button again to return to the item selection display.
Press the [Tenkey –] or [Tenkey +] button to select the next test item.
In the acceptable selection screen, each character of the item number will be followed by dot "." on the 7-segment LED,
so that you can see later if it has already been checked.
If the result is NG, press the [SONG/STYLE] button or the lowest key (white key C1) to return to the item selection display.
Auto mode
The operation method follows a manual mode.
PSR-F50
17