Aleko AC 1500 Kullanıcı Kılavuzu - Sayfa 13

Kapı Açıcı Aleko AC 1500 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Aleko AC 1500 16 sayfaları. Sliding

Aleko AC 1500 Kullanıcı Kılavuzu
DIP Switch #1– #2: Running time of the motor in Midway Mode
DIP Switch #1: ON –2 Seconds OFF –0
DIP Switch #2: ON –4 Seconds OFF –0
NOTE: The midway mode function would be disabled if both DIP switches are turned off. Factory
default setting is disabled.
E.g.
Running time of the operator in pedestrian mode is 2 seconds.
DIP Switch #3: Auto close function enabled/disabled
DIP Switch #3: ON –auto close function enabled
OFF –auto close function disabled
E.g.
Auto close function of the opener has been enabled. Factory default setting is disabled.
DIP Switch #4: Left/Right open
2. Potentiometers
Potentiometer A and B are used to adjust the stall force and auto close time of the gate operator separately.
Turn potentiometer A clockwise to increase the stall force, and turn it counter-clockwise to decrease the
stall force.
Turn potentiometer B clockwise to increase the auto close time, and turn it counter-clockwise to decrease
the auto close time, the auto close time could be adjusted steplessly from 1 to 99 seconds.
12