SER 9616-A
Operation
WARNING
Do not exceed the lowest pressure rating
of any component in the system.
Never point a control valve at any portion of your
body or another person. Lubricant discharged at
high velocity can penetrate the skin and cause
severe injury. Should any fluid appear to puncture
the skin, get medical care immediately.
Ensure all components are in operable condition.
Replace any suspect parts prior to operation.
Personal injury can occur.
1. Make sure air pressure at the regulator reads zero.
2. Slowly supply air pressure [not to exceed 20 psi
(1.4 Bars] to the pump's motor.
• The pump assembly should cycle.
If the pump assembly does not cycle, refer to the
Troubleshooting Chart for details.
With air pressure at zero:
3. Connect a product hose to the pump's material outlet.
• Direct the hose into an appropriate container.
4. Place the pump in the product to be dispensed.
5. Slowly supply air pressure to the pump's motor.
6. Allow the pump to cycle slowly until the system and
product is free of air.
If the pump assembly does not prime, refer to the
Troubleshooting Chart for details.
WARNING
Should leakage occur anywhere within the
system, disconnect air to the motor. Personal
injury can occur.
With air pressure at zero:
7. Attach a control valve to the outlet hose of the pump.
8. Slowly supply 35 psi (2.4 Bars] air pressure to the
pump's motor.
9. Operate the control valve into a container.
Revision (10-98)
1-800-548-1191-http://[email protected]
10. Allow the pump to cycle until the system and product
is once again free of air.
11. Shut off the control valve.
12. Set the air pressure to 100 psi (6.9 Bar).
13. Visually inspect the pump for external leaks.
• The pump should not cycle.
If the pump does not stall, refer to the
Troubleshooting Chart for details.
14. Check the motor for air leakage.
If the motor leaks, refer to the Troubleshooting Chart
in the Air Motor Service Guide for details.
Installation
Additional items that should be incorporated into the
air piping systems are listed in Table 4.
Part Number
5604-2
Moisture Separator
7604-B
Regulator and Gauge
Table 4 Air Line Components
8
Low-Pressure Transfer Pump
Description
Alemite Corporation