Ayrıca CAME Z Series için: Manuel (8 sayfalar), Manuel (20 sayfalar), Manuel (4 sayfalar), Manuel (4 sayfalar), Manuel (17 sayfalar), Manuel (17 sayfalar), Manuel (13 sayfalar), Manuel (13 sayfalar), Manuel (16 sayfalar), Manuel (16 sayfalar), Manuel (12 sayfalar), Manuel (12 sayfalar), Manuel (18 sayfalar), Manuel (8 sayfalar), Manuel (20 sayfalar), Manuel (12 sayfalar), Manuel (12 sayfalar), Teknik Dokümantasyon Kılavuzu (16 sayfalar), Talimatlar Kılavuzu (16 sayfalar), Talimatlar (4 sayfalar), Hızlı Kılavuz (2 sayfalar), Bağlantı Kılavuzu (4 sayfalar), Manuel (4 sayfalar), Manuel (12 sayfalar), Manuel (20 sayfalar), Manuel (15 sayfalar), Kullanım Kılavuzu (12 sayfalar), Hızlı Başlangıç Kılavuzu (12 sayfalar), Manuel (16 sayfalar)

CAME Z Series Kurulum Kılavuzu

5.6 Function selection

1 ON - Pre-fl ashing upon opening and closing – Following an opening or closing command, the fl ashing light connected on
E1-E2, fl ashes for 5 seconds before the cycle begins.
2 ON - Automatic closing – the timer for the automatic closing is activated when the door completes its opening cycle. The set
time is adjustable, and it is any how conditioned by the possible intervention of the safety devices and dies not activate
after a total safety 'stop' or during a power outage.
N.B.: If «maintained action» mode is selected, check that the automatic closure function is disactivated (2 OFF).
3 ON - Detection of obstacle – When motor is not running (gate closed, open or after a total stop command), prevents any
movement if the safety devices (e.g. the photocells) detect an obstacle
4ON / 5OFF - open only' function with radio transmitter (with radio frequency card inserted).
5ON/ 4OFF - 'open-close-inversion' function with button (2-7) and radio transmitter (with radio frequency card inserted).
5.7 Adjustments
Trimmer TL. = regulates the motor working time, for each single opening or closing, it has a range of 2 to 60 seconds
Trimmer T.C.A. = Adjusts the waiting time in the opening position. Once this time frame has lapsed, an automatic closing pro-
cedure is performed. The waiting time may be adjusted to between 3 second and 60 seconds. Adjusting to the minimum excludes
the automatic closing function.
Trimmer T.R.2M. = Adjusts the waiting time closure delay for 2nd motor (3 to 10 seconds)
8
ON
OFF