Safety devices
Delta
Reopening during closing connection (contact NC). With safety devices such as photocells, sensitive safety-
edges and other EN 12978 regulation compliant devices. When closing, the contact triggers the inversion of
movement until opening is complete.
with DIP-switch 8 OFF - DIP-switch 2 OFF
(Selector
Connection for reopening during closing (contact
NC). - With safety devices such as photocells, sensitive
safety-edges and other EN 12978 regulation compliant
devices. When opening, the contact triggers the
inversion of movement until closing is completed.
Safety test function connection - With each opening and closing command, the board checks the efficiency of
the photocells. Any malfunction of the photocells is warned by the flashing LED
cancels any command from the radio transmitter or button.
IMPORTANT: When activating the safety test feature, at least one pair of photocells must be connected in
"reopening during closing" (C1).
<- C1 ->
If unused, short-circuit 2-C1.
<- CX ->
)
If unused, disable input CX with DIP-switch 8 set to ON.
<- TS ->
with DIP-switch 10 ON
Dir/DeltaS
with DIP-switch 8 OFF - DIP-switch 2 ON
(Selector
Partial stop connection (contact NC). - With safety
devices such as photocells, sensitive safety-edges and
other EN 12978 regulation compliant devices. Stops
movement and then triggers automatic closing.
)
on the control board, which