functions selection
Selector
1 ON
Automatic closing activated (1 OFF - deactivated);
2 ON
"Open-stop-close-stop" with button (2-7) and radio-control
(AF card fi tted) activated;
2 OFF
"Open-close" with button (2-7) and radio-control (AF card
fi tted) activated; 3 ON
(AF card fi tted) activated (3 OFF-deactivated);
4 ON
Pre-fl ashing while opening and closing activated (4 OFF-
deactivated)
5 ON
Obstruction detection activated (5 OFF-deactivated);
6 OFF
"Maintained action" (excludes functioning of the radio
control) deactivated (6 ON-activated);
7 ON
Ram-jolt activated; with each opening command, the
gate-leaves at fi nal closing point press for one second,
thus facilitating the releasing of the electrolock which
is connected to terminals 11-S. It is active only if the
gate-leaves are closed and the end of the working time,
or at the 1st maneuver after powering up the system (7
OFF-deactivated);
8 OFF
Terminal CX activated (8 ON-deactivated);
9 OFF
Ten-second slow-down deactivated (9 OFF.-activated);
10 ON
Photocells test activated (10 OFF deactivated).
Trimmer adjusting
Adjusting working time from a minimum of 10 seconds to a
maximum of 120 seconds.
Adjusting the automatic closing time from a minimum of 1
second, to a maximum of 120 seconds.
Adjusting delayed closing of 2nd motor (min. 0", max. 15")
and simultaneously partial opening (min. 0", max. 30").
Adjusting slow-down speed
To adjust the slow-down speed (operation to be done with gate stopped):
•
set DIP-switch 6 to ON;
•
press CH1, the red LED
(see table);
•
by pressing CH1 again it shifts to the next speed;
•
confirm the choice by pressing CH2;
•
reset DIP-switch 6 to OFF.
"Open only" with radio-control
will show the set slow-down speed
Selector
1 ON
Limit switches enabled (1 OFF -
disabled);
2 OFF
CX with reclosing during opening
feature.
2 ON
CX with partial stop feature.
Flashing in quick
succession
minimum
medium
maximum
L2T
1
2
3
4
L1T
0
12 24
L1T
L2T
CT
0 12 24
2
FA1
FC1 FA2 FC2
L
N
U
V
W
X
Y
E E3
TS 10
10 11
S
1
2
3 3P 4
5
7
2 C1 CX B1 B2
L2T
1
2
3
4
L1T
0
12 24
L1T
L2T
CT
0 12 24
2
FA1
FC1 FA2 FC2
L
N
U
V
W
X
Y
E E3
TS 10
10 11
S
1
2
3 3P 4
5
7
2 C1 CX B1 B2
Slow-down
speed 1
2
3