Acoustic Remedy ClimaCab Kurulum ve Kullanım - Sayfa 6

Müzik Ekipmanları Acoustic Remedy ClimaCab için çevrimiçi göz atın veya pdf Kurulum ve Kullanım indirin. Acoustic Remedy ClimaCab 10 sayfaları.

A C O U S T I C R E M E D Y
C L I M A C A B
S E T
U P
A N D
U S E
SET UP AND USE DIRECTIONS
7.) continued....
magnetically lock them to the rails permanently affixed to the floor of the ClimaCab. Move the rails
inward and outward to the proper position relative to one another.
For the ProHang Display/Storage Option, follow the instructions for the Top Rail and then when
the String Swing hangers into the slat wall, locate the small lip on the upper edge of the black
plate. Tilt the hanger slightly from vertical and insert the lip into the opening between the slats.
8.) Once the hangers are inserted, put them into the approximate location along the Top Rail, Neck
Wedge Rail, or Slat Wall based on the instruments you plan to store.
9.) Remove the humidifier reservoir from the box and place into the recessed portion in the floor of
the ClimaCab. The orientation of the humidifier reservoir should be such that the fill/air flow port is
toward the back for the ClimaCab. The fill/air flow port is located opposite of the fan and will
come with a slotted cover plate inserted into the hole.
10.) Thread the black wire inside the recessed box onto the nut on the side of the reservoir. The
wire will have 4 prongs on the end that must line up with the four holes on the reservoir side. Plug
in the cord leaving the back of the ClimaCab (which is from the power supply strip mounted inside
the humidifier box) into a standard outlet. Ensure that the light on the power strip is illuminated by
looking for the orange indicator light. If not, turn on power strip. Ensure the LED light strip and
humidifier power supplies are plugged into the power strip. Once the power strip is plugged in, the
LED light strip will be illuminated and the humidifier control box mounted to the rear center of the
cabinet will illuminate. It will automatically enter Standby mode for 10 minutes. Hold the menu
button and up arrow simultaneously to bypass Standby mode.
11.) Fill the humidifier to the max fill line with distilled water. NOTE: you can fill the reservoir with
less water until the warning on the control box stops flashing.. Once the desired amount of water is
inside the reservoir, you can opt to replace the slotted fill/air port cover plate or leave it out. Under
most circumstances, you'll want to leave the cover plate off. This is designed to be used during
higher humidity situations where passive evaporation is a concern and also when restricting air
flow would be beneficial. NOTE: The Neck/Bout Rest Storage/Display Option comes
automatically with a funnel and tube system to fill the humidifier without have to remove the Bout
Rails. Also, it's recommended to add a few drops of bacteriostat to each fill of the humidifier
reservoir to keep bacteria and mold growth from occurring.