Data Output:
1_OWD1_1|8
1_OWD1_2|10000000
1_OWD1_3|3
1_OWD1_4|00000111
Further information regarding options and commands can be found in the latest available documentation for
1–Wire Controller / 1–Wire Gateway.
12
Operating conditions
The module may only be operated at the voltages and ambient conditions specified for it. The device can be
operated in any position. The device is intended for use in dry and dust-free rooms.
If condensation forms, wait at least 2 hours for the device to acclimatize.
Assemblies and components must not be handled by children!
The modules may only be put into operation under the supervision of a qualified electrician.
In commercial facilities the accident prevention regulations of the association of the commercial trade
associations for electrical systems and equipment must be observed.
Do not operate the module in an environment where flammable gases, vapors or dusts are present or could be
present.
13
Assembly
The installation site must be protected against moisture. The device may only be used in dry indoor rooms and in
protected outdoor areas. The device is intended for mounting inside a switch cabinet as a stationary
device.
14
Disposal
Note
Do not dispose of this device in the household waste. Electronic devices must be disposed in
accordance with directives for disposing of waste electrical and electronic equipment at local
collection points for electronic waste material.
15
Safety instructions
When using products that come into contact with electrical voltage, the valid VDE regulations must be
observed, especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860
During final works and wiring works power has to be de-connected.
Before opening the device, always unplug and make sure that the unit is disconnected from the mains.
Components, modules or devices may only be put into service if they are mounted in a contact proof housing. During
installation they must not have power applied.
Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected
from the power supply and electrical charges stored in the components inside the device have been discharged.
Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or
breaks.
If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable
has been replaced.
When using components or modules it is absolutely necessary to comply with the requirements set out in the
accompanying description specifications for electrical quantities.
If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics for
a part or assembly are, how to connect an external circuit, which external components or additional devices can be
connected or which values these external components may have, a qualified electrician must be consulted.
It must be examined generally before the commissioning of a device, whether this device or module is basically
suitable for the application in which it is to be used.
In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary.
For operational and connection errors outside of our control, we assume no liability of any kind for any resulting
damage.
Kits should be returned without their housing when not functional with an exact error description and the
accompanying instructions. Without an error description it is not possible to repair the device. For time-consuming
assembly or disassembly of cases charges will be invoiced.
During installation and handling of components which later have mains potential on their parts, the relevant VDE
regulations must be observed.
Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified
electrician and put into operation.
Commissioning may only be realized if the circuit is built into a contact proof housing.
If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be installed
upstream or a suitable power supply can be used.
After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance,
https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance) must be carried out.
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de
=> controller no._module no._data set | input decimal value
=> controller no._module no._data set | input binary display
=> controller no._module no._data set | output decimal value
=> controller no._module no._data set | output binary display
11220 V2.0 R1.0 Manual