ClearWater AQUA ELITE 50 Kurulum ve Bakım Kılavuzu - Sayfa 5

Aydınlatma Ekipmanları ClearWater AQUA ELITE 50 için çevrimiçi göz atın veya pdf Kurulum ve Bakım Kılavuzu indirin. ClearWater AQUA ELITE 50 20 sayfaları.

Generously wrap Teflon tape around the threaded part of the electrode assembly
several times. Screw electrode into the tee. Do not over tighten.
G). INSTALLING THE VENTURI INJECTOR
Power Source/
Pump Timer
Pump
Filter
N = Nylon Hose Clamps
Mount the venturi manifold on the return line (after the filter, pump, electrode chamber, heater, etc.) so it is the
last item before entering the pool. This is very important.
MAKE SURE THE WATER FLOWS IN THE DIRECTION OF THE ARROWS MARKED ON THE
VENTURI MANIFOLD.
The venturi manifold comes in two-inch pipe. If plumbing size is 1 ½", you will need to add 2" x 1 ½" reduced
bushings on each end of the manifold (included with the venturi manifold package.)
F). INSTALLING THE ELECTRODE
N
N
Electrode
N
2" manifold with
venturi injector and
ball valve assembly
Heater
1½" reducer bushings (if needed)
5
N = Nylon Hose Clamps
Kynar check valve
¼" reinforced vinyl hose
Venturi Injector
Clear view window
water flow
N
POOL