AIMS Power GEN6600W240VS Manuel - Sayfa 10

İnvertör AIMS Power GEN6600W240VS için çevrimiçi göz atın veya pdf Manuel indirin. AIMS Power GEN6600W240VS 20 sayfaları. Portable inverter generator

AIMS Power GEN6600W240VS Manuel
 Be sure the outlet load current is within outlet's rated current.
 The economy control switch must be turned to "OFF" when using electric
devices that require a large starting current, such as a compressor or a
submersible pump. FIG.20
OVERLOAD INDICATOR LIGHT
The overload indicator light comes on when overloaded, short circuit, or voltage
is out of operating tolerance, or the AV output voltage rises. The electronic
breaker will then activate, stopping power to the generator in order to protect
the generator and any connected electric devices. The overload indicator light
(red) will flicker and then keep on, the generator will stop power output. If so
please follow the following steps: FIG.21
(a)
Reduce the total wattage of connected electric devices within the
application range.
(b)
Check for blockages in the cooling air inlet and around the control unit. If
any blockages are found, remove.
(c)
Press the "RESET" button to reset the output, FIG.22
CAUTION:
 The generator AC output automatically resets when the engine is stopped and then restarted.
 The overload indicator light may come on for a few seconds at first when using electric devices that require a large
starting current, such as a compressor or a submergible pump. This is not a malfunction.
2. DC APPLICATION
12V battery charging only. FIG.23
(a) 12V DC socket maybe use to charge cell phones and other small
electronics using a 12DC adapter
(b) When charging batteries, make sure to properly connect the leads to the
battery. Do not reverse the polarity.
9
FIG.20
FIG.21
FIG.22
V
A
KW
HZ
MODE
RESET
FIG.23