Setting up the mPro200GC-AP
EN
8.
Confirm settings with <OK>.
9.
Press <Apply>.
→ Settings are written onto the tool.
10. Confirm the following message with <Yes>:
Toolserial: xxxxxxx
Builddate: xx.xx.xx
Configure Tool?
11. Confirm the following message with <OK>:
Configuration done!
12. Installing the tool on the controller.
3.4
Configuring tool Bluetooth settings with mPro200GC-AP
Perform the following steps only when Bluetooth communication is to be established. For WLAN communi-
cation see chapter 3.3 Configuring tool RF settings with the PC, page 10.
1.
Switch on the tool.
2.
Using mProRemote Professional to access the controller and select Navigator > Utility > System-Set-
tings > Radio Frequency (RF) Configuration LiveWire/CellCore.
3.
Open the Bluetooth AP Configuration tab.
4.
Select the Activate Bluetooth Communication check box.
5.
Press <Start pairing...>.
6.
Activate Bluetooth on the tool: Select
7.
Use the tool to scan for Bluetooth devices: Select
8.
Select the desired controller
→ When the Bluetooth connection is established, the field is highlighted in green.
9.
Set the node number: Select
10. Installing the tool on the controller.
12
Parameter
Wireless channel
<Scan channels>
Transmit power
Roaming Aggressive-
ness
<OK>
<Cancel>
Description
There are two setting options:
•
Select Auto after the corresponding channel is automatically
searched for.
•
Assign the channel selected during the WLAN configuration.
Scan wireless channels. The button is not active if a channel is selected
for Wireless channel.
When using the mPro200GC-AP, this function is not needed because
only one channel can be selected.
Set transmission power.
Setting option, from which signal strength the tool connects with another
access point.
Select Low because the access point is integrated in the controller for
the mPro200GC-AP.
Exit input window; the settings are saved.
Exit input window; the settings are not saved.
>
>
>
>
and confirm with the
>
>
.