DLX XW-70 Manuel - Sayfa 6

Isıtıcı DLX XW-70 için çevrimiçi göz atın veya pdf Manuel indirin. DLX XW-70 10 sayfaları.

/ /
P RE-O P ERATI ON & BAS IC SET UP
PRE-STARTUP PROCEDURES
1. Check the heater thoroughly for damage. DO NOT operate a damaged heater.
2. Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods or
persons due to improper use.
3. Ensure fire-fighting equipment is available and suitable to the potential of the heater.
4. Check that the fuel is the appropriate type for this unit (#1 or #2 fuel oil, or kerosene).
5. Check that there is sufficient fuel in the fuel tank by reading the fuel gauge embedded near the fuel filter.
6. If not already closed, close the tank cap by rotating it clockwise. It is recommended to use winter diesel oil below ambient temperatures of 41 °F.
7. Ensure minimum safety clearances from combustibles is achieved in all directions.
8. Make sure that flue gas is adequately ventilated from the chimney.
9. Plug in supply cord to 115V minimum 15 A outlet.
TURNING ON THE HEATER
Refer to the diagram for the layout of the control panel (
). The heater turns on by
FIG. 3
flipping the power switch from "OFF" to "ON". The burner box will begin firing, which will
heat up the combustion chamber. Within 30 seconds the blower fan will activate.
NOTE: If the heater switches off due to a lack of fuel, top off the tank and reset the heater
(see page 6).
EXTERNAL THERMOSTAT SOCKET
The heater will only work automatically when a control device, such as the included
thermostat, is connected to the heater. Connect by removing the thermostat socket cap
FIG. 3
and connecting the thermostat to the socket. If no thermostat will be connected the cap
must be inserted into the socket.
/ / / /
DEPL OYEDLOGIX.C OM //
@ DE PLOYEDL OGIX // EM AIL : SA L ES @D EP LO YE DL OG IX .C OM / / P: 5 4 1 .3 5 7 .5 9 78
5
©️ 2021 D LX E NTE R PR ISE S LLC . // V E RS ION 1. 01