Clockaudio CDT100 Kullanıcı Kılavuzu - Sayfa 15

Aksesuarlar Clockaudio CDT100 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Clockaudio CDT100 17 sayfaları. Dante transporter
Ayrıca Clockaudio CDT100 için: Kullanıcı Kılavuzu (16 sayfalar)

7.1 – Crestron
Simple Windows Name: Clock_Audio_CDT100_Module
Summary:
This module provides control and feedback of the Clockaudio CDT100 via UDP. It also provides true feedback.
General Notes:
 Pulse the Initialize input before performing any other operations.
 The module utilizes a "Heartbeat" to maintain communication with the CDT100. This heartbeat will begin once preliminary
initialization is complete.
 Should a heartbeat response not be received, the module will attempt to send the heartbeat two more times in succession.
 If neither of these responses are received, the module will consider communication with the CDT100 to be broken, it will clear
all existing data and output signals, and will attempt to re-establish communication with the CDT100 every 10 seconds.
 Once communication has been re-established, the module will automatically re-initialize.
 The module will automatically subscribe for available unsolicited feedback with the CDT100 upon initialization.
Crestron Hardware Required: 3 Series Compatible only
Setup of Crestron Hardware:
 Connect Crestron 3-series processor via Ethernet port of same network that CDT100 is on.
 Configure IP address of both Crestron and CDT100. (Ensure subnet settings match).
Vendor Firmware: 99.5
OPS Used for Testing: RMC3 (1.010.0060)
Sample Program: Clock_Audio_CDT100_Demo
Download the Crestron interface module and application notes from the CDT100 product / Technical Downloads section of the
website www.clockaudio.com.
©
Clockaudio 2015
15
CDT100 User Manual